background image

PAGE   9

SB-8180 INSTRUCTION & OPERATION MANUAL

RS-232 SERIAL COMMANDS

FRONT PANEL LOCK 

 

Note : Hard resetting the unit will unlock the Front Panel controls. 

SBSYSMLK

 

- When front panel is locked, changes can only be 

  

made by RS232

SBSYSMUK

 

- Front Panel Unlock

Unit will respond with

SBSYSLOK

 

- Front Panel has been Locked

SBSYSULK

 

- Front Panel has been Unlocked

Example : Lock Front Panel Buttons

SBSYSMLK

-Send

SBSYSLOK

-Rcvd

UNIT RESET

SBALLRST

 

- Reset every output to Input 1

Unit will respond with

SBRSTACK

 

- Unit has reset each Output to Input 1

Example : Reset all outputs to Input 1

SBALLRST

-Send

SBRSTACK

 

-Rcvd

Power Off mode.

 

- Put system into Standby (Soft Power Off)

 

- Bring unit out of Standby (Soft Power On)

Unit will respond with

 

- Unit is in Standby

SBALONAK

 

- Unit is no longer in Standby

Example : Put Unit in Standby (Soft Power)

SBSYSMOF

-Send

SBALOFAK

 

-Rcvd

SBALOFAK

SBSYSMON

SBSYSMOF

MORE STUFF FOR SB-8180

 

Note: 

 

 
 

Turning the unit System Power Off over RS232 will distinguish the LED display leaving only the Power 
Switch LED on. The Video and Audio outputs will also mute.  While the unit is turned off by RS232 it will 
continue to accept and act upon switching commands.  For example, if the unit is in the off mode 
(via RS232) and you send a command to switch an input to an output,  that route will complete and the 
video and audio will now appear on that channel only.  The front panel LED for that particular output will 
also show the input selected (for that single output channel only).  The remaining LED

s will remain off 

and video and audio outputs muted.  The unit will still return status and change messages in response 
to commands sent while in Power Off state. A hard reset command (SBALLRST) will return the unit to 
normal operation and also unlock the front panel.

Summary of Contents for SB-8180

Page 1: ...y to install and highly reliable but it is essential that you read this manual throughly before attempting to use 8x8 VGA Matrix Switcher 8x8 VGA Matrix Switcher Series 8x8 VGA MATRIX SWITCHER 8x8 VGA...

Page 2: ...which may impede the normal flow of air around the unit 13 such as a bed rug carpet or completely enclosed rack If the unit is used in an extremely dusty or smoky environment the unit should be Period...

Page 3: ...VAC Before attempting to use this unit please check the packaging and make certain the following items are contained in the shipping carton Note Please retain the original packing material should the...

Page 4: ...the signals on the devices you have connected to the various output connectors of the switcher EXP HOW TO SWITCH CH 08 WHEN WORKING ON CH 01 Please press Select push button till CH 08 then press SET p...

Page 5: ...or displays INPUT 1 2 INPUT 1 2 1 1 2 2 VGA VGA VGA RGBHV Via 1x HD 15p connector Note With 1x female D Sub connector OUTPUT 1 2 OUTPUT 1 2 1 1 2 2 VGA VGA RoHS 95 EC INPUT DC 12V RS 232 RS 232 INPUT...

Page 6: ...ween the output of the device you wish to distribute to output s of the switcher to the carious devices you wish to feed a signal to Lastly connect the AC to DC adaptor connect the DC connector to the...

Page 7: ...trols Attached Window based control software for Desktop or NB control by RS232 port Manual controlled by Front Panel button IR remote control 11 Support desktop with Ear mount and 19 inch Rack mounta...

Page 8: ...ntrol If the unit needs to be controlled via the front panel in addition to the RS232 control you should regularly poll the unit status to ensure the control system accurately reflectes the current se...

Page 9: ...xample Put Unit in Standby Soft Power SBSYSMOF Send SBALOFAK Rcvd SBALOFAK SBSYSMON SBSYSMOF MORE STUFF FOR SB 8180 Note Turning the unit System Power Off over RS232 will distinguish the LED display l...

Page 10: ...IR RS232 INTERFACE SYSTEM PORTS CONTROL PORTS 1 IR REMOTE IR Remote Controller SB 8180 8x VGA source devices to 8x VGA Display Matrix Switcher 2 RS 232 Interface RS 232 interface system VIDEO VGA RGBH...

Page 11: ...CE The product complies with the relevant standards for CE FCC and RoHS approval The power Adaptor Supply has been tested for compliance with UL CSA and CE standards TROUBLESHOOTING If you experience...

Page 12: ...tween the controller and 8 ASCII bytes 3 Controlling commands from a controller to The ASCII bytes indicate the action of the command as ASCII format 4 Feedback commands from to a controller The 8 ASC...

Page 13: ...U A L Meicheng R Meicheng R Address 13F No 2 Jian 8th Rd Jhonghe City Taipei County 23511 TAIWAN Website www meicheng com tw Email mei cheng msa hinet net Te l 8 8 6 2 8 2 2 8 0 3 11 F a x 8 8 6 2 8 2...

Reviews: