HT  6550200200

 

KC-326B HUMIDITY AND ENVIRONMENTAL PRESSURE METER 

Page - 11 

◦ If you use only the battery, the recorded data will be saved before the low battery 

symbol appears. After the low battery 

symbol appears, the recording will stop and save the previous data. If the device has the low battery symbol activated, you 
cannot save any data. 

◦ Connect the 5V power supply instead of downloading data via USB, the P

C connection symbol will not appear. At this 

time, only external power is supplied. By connecting the 5V power supply you can ensure that the unit will work for a long 
period of time and will not shut down. When connecting the power or external USB to the  PC, the device will cancel the 
auto power off function. The "APO" symbol will disappear. The recording function will not be changed. 
 

 

Adjustment of PC and data transmission 

 

 

 

◦ When connecting the device, if the unit is in the auto

-recording state,  you  need  to  exit to  the  manual  state 

(the "LOG" symbol will disappear from the display) to continue communication with the PC. 

 

◦ Connect the PC via USB, 

and the symbol will appear on the screen. This will indicate that the connection 

has  been  made  correctly.  At  this  time,  we  can  use  the  PC  to  perform  the  configuration  and  download  data 
(please refer to the user manual). The unit will cancel the auto power off function and the "APO" symbol will 
disappear.  After  the  communication,  close  the  program,  the  PC  symbol  will  not  disappear  and  the  data 
recording will stop. Disconnect the USB cable from the PC and the PC connection symbol

 disappears and a 

new recording can be made. 

  After  successful  connection  and  data  transfer,  do  not  work  with  the  device.  When  disconnecting  the  device 

from the PC, turn the unit off and on again to continue working. 

 

 

Device lighting control

 

 

◦ The device ligh

t will turn off if there is no action after 30 seconds. 

 

 

Auto Power Off Settings

 

   

 

◦ Press the power button and the "APO" symbol will be displayed on the screen. The device will turn itself off in 

30 minutes with 3 beeps. 

 

◦  Press  the  ZERO/WBT  button  to  turn  on  the  device  again  and  the  "APO"  symbol  will  disappear. 

The  Auto 

Power Off Function.  

 

Note: When the auto recording mode is on or the external power supply is connected, the auto power off function 
stops automatically and the "APO" symbol will disappear.. 

 
 

 

PRECAUTIONS 

 

- Do not drop the product or use it by force. 

- Do not disassemble the product to avoid breakdowns. 

- Replace the protective cap when not in use. 

- Do not place the product with corrosive gas. 

- Keep the device clean. 

- Avoid dust and water. 

- Do not immerse the product in water as it will be damaged. 

 

- Please remove the battery if you are not going to use it for a 

while..

 

 

 
 
 
 
 
 
 
 
 

Summary of Contents for KC-326B

Page 1: ...medical supplies warehouse and home decoration Safety instrucctions Failure to follow the instructions below may result in electric shock or personal injury Please read this manual carefully before using this product Do not remove any labels from this product Do not use the product in the presence of explosive or flammable gases Please take care with the probe and do not damage it When you have fi...

Page 2: ...on Press once to turn on the device Press again to set the data Press and hold this button for 2s to turn it off M Moisture probe interface in wood N Mini USB interface Display Screen Illustration 1 Indicator arrow 2 RH Relative humidity mode 3 AH Absolute Moisture Mode 4 DEW Dew point mode 5 COND Condensation surface temperature dew point mode 6 MR Mixing ratio mode 7 BP Ambient pressure mode 8 V...

Page 3: ...rew and open the battery cover insert a 9V battery and replace the battery cover Press the power button and the device will turn on Hold the power button for 2s or wait 30s for it to auto power off RH Mode Relative Humidity The default mode after power up is RH or press the DN or UP button to move the RH indicator date to another mode Press the ZERO WBT button under this mode and it will change fr...

Page 4: ...the unit on press the DN or UP button to move the indicating arrow from left to right to COND mode If the thermocouple probe is not connected will be displayed If the probe is connected the first row shows the temperature difference at the dew point and the second row shows the temperature value recorded by the thermocouple can be considered as the surface temperature Press the UNIT button to togg...

Page 5: ...played on the screen The memory serial number will automatically increase by 1 Mode BP ambient pressure Turn on the unit press the DN or UP button to move the indicating arrow from left to right to BP mode Press the UNIT button to switch between KPa and mBAR Press the STORE ENTER button for 2 seconds to record the data displayed on the screen The memory serial number will automatically increase by...

Page 6: ... be measured Press the ZERO button and the ZERO symbol will appear Seconds later the ZERO symbol disappears Press the UNIT button to exchange ºC ºF Press the STORE ENTER button for 2 seconds to record the data displayed on the screen The memory serial number will automatically increase by 1 Mode Me humidity with external probe Turn on the unit press the DN or UP button to move the indicating arrow...

Page 7: ... OFF to deactivate the alarm The factory defaults are 25 and 85 1 Setting the Humidity Alarm Limits Press and hold the MAX MIN and UNIT buttons simultaneously under RH mode the HIGH symbol will be displayed on the screen Set the alarm limit to OFF to disable the alarm function Press the DN or UP button to change the upper alarm limit and hold it down to quickly increase or decrease the value Press...

Page 8: ...r UP buttons to change the memory serial number the corresponding data will be displayed To exit this mode press the STORE ENTER button to return to the previous mode To delete all data in memory press and hold the ZERO WBT button and UNIT button to delete all stored data and the serial number will return to 01 with 3 beeps Review of parameters related to automatic recording Press the LOG SET butt...

Page 9: ...o move the arrow to INT Press LOG SET to confirm and enter the settings and the last two digits under the display will flash Press the UNIT or STORE ENTER button to change the value S M H indicates second minute and hour respectively Press the LOG SET button to save the current flashing digits Press the DN or UP button to exit this setting without saving and enter other environments Press the HOLD...

Page 10: ... configurable parameters will return to factory settings Press the DN or UP button to exit this setting Press the HOLD button to exit review and adjust mode and return to normal mode Automatic data recording Under normal measurement conditions press the LOG SET button for 2 seconds and the LOG and JOB symbols and data will be displayed on the screen The device will record according to the paramete...

Page 11: ...download data please refer to the user manual The unit will cancel the auto power off function and the APO symbol will disappear After the communication close the program the PC symbol will not disappear and the data recording will stop Disconnect the USB cable from the PC and the PC connection symbol disappears and a new recording can be made After successful connection and data transfer do not w...

Page 12: ... 8000 Automatic screen shutdown 30 seconds no activity Automatic device shutdown 30 minutes no activity PC Interface USB 2 0 Accessories Humidity sonde wire USB y CD Optional accessories Termocouple K type not included Power supply A battery 9V 6F22 6LR61 Intensity of work 25mA Working temperature 0ºC 43ºC Working Humidity 5 95 HR without condensation Storage 30ºC 60ºC 90 HR without battery Dimens...

Reviews: