KC-326B HUMIDITY AND ENVIRONMENTAL PRESSURE METER 

Page - 1 

 
 

HUMIDITY AND AMBIENT PRESSURE METER WITH HUMIDITY PROBE KC-326B 

 

Introduction:

 

 
The  KC-326B  Humidity  and  Environmental  Pressure  Meter  incorporates  several  energy 
saving  sensors  in  a  compact  design.  It  measures  in  real  time  the  ambient  temperature, 
humidity,  atmospheric  pressure,  moisture  content  of  a  piece  of  wood  and  can  quickly 
calculate  the  dew  temperature,  absolute  humidity  (g/kg  and  grains/pounds),  wet  bulb 
temperature,  and  steam  pressure  with  the  dew-surface  temperature  calculation  mode,  20 
data  retention  groups  in memory  and  8000  groups of  automatic  data  recording.  The  device 
has a  large  screen  with  two  LCDs  with intelligent  management.  It  is  an  ideal  instrument  for 
monitoring food, medical supplies, warehouse and home decoration..

 

 
 

Safety instrucctions

 

 

Failure to follow the instructions below may result in electric shock or personal injury. 
 

 

- Please read this manual carefully before using this product. 

 

- Do not remove any labels from this product. 

 

- Do not use the product in the presence of explosive or flammable gases. 

 

- Please take care with the probe and do not damage it. When you have finished using it, put on the  protective 
cap. 

 

- The probe is sharp. Be careful when using it. 

 

- Keep the product out of the reach of children.. 

 
 

Battery Safety Instructions 

 

 

- Please remove the batteries when cleaning this product. 

 

- Remove the batteries before storing the device for a long period of time. 

 

- Please insert the batteries correctly as the negative and positive pole instructions indicate. 

 

- Please dispose of the batteries correctly. High temperatures can cause explosions. 

 

- Place insulating tape around the battery to avoid contact with other objects..

 

 
 

Product details

 

 

 

Summary of Contents for KC-326B

Page 1: ...medical supplies warehouse and home decoration Safety instrucctions Failure to follow the instructions below may result in electric shock or personal injury Please read this manual carefully before using this product Do not remove any labels from this product Do not use the product in the presence of explosive or flammable gases Please take care with the probe and do not damage it When you have fi...

Page 2: ...on Press once to turn on the device Press again to set the data Press and hold this button for 2s to turn it off M Moisture probe interface in wood N Mini USB interface Display Screen Illustration 1 Indicator arrow 2 RH Relative humidity mode 3 AH Absolute Moisture Mode 4 DEW Dew point mode 5 COND Condensation surface temperature dew point mode 6 MR Mixing ratio mode 7 BP Ambient pressure mode 8 V...

Page 3: ...rew and open the battery cover insert a 9V battery and replace the battery cover Press the power button and the device will turn on Hold the power button for 2s or wait 30s for it to auto power off RH Mode Relative Humidity The default mode after power up is RH or press the DN or UP button to move the RH indicator date to another mode Press the ZERO WBT button under this mode and it will change fr...

Page 4: ...the unit on press the DN or UP button to move the indicating arrow from left to right to COND mode If the thermocouple probe is not connected will be displayed If the probe is connected the first row shows the temperature difference at the dew point and the second row shows the temperature value recorded by the thermocouple can be considered as the surface temperature Press the UNIT button to togg...

Page 5: ...played on the screen The memory serial number will automatically increase by 1 Mode BP ambient pressure Turn on the unit press the DN or UP button to move the indicating arrow from left to right to BP mode Press the UNIT button to switch between KPa and mBAR Press the STORE ENTER button for 2 seconds to record the data displayed on the screen The memory serial number will automatically increase by...

Page 6: ... be measured Press the ZERO button and the ZERO symbol will appear Seconds later the ZERO symbol disappears Press the UNIT button to exchange ºC ºF Press the STORE ENTER button for 2 seconds to record the data displayed on the screen The memory serial number will automatically increase by 1 Mode Me humidity with external probe Turn on the unit press the DN or UP button to move the indicating arrow...

Page 7: ... OFF to deactivate the alarm The factory defaults are 25 and 85 1 Setting the Humidity Alarm Limits Press and hold the MAX MIN and UNIT buttons simultaneously under RH mode the HIGH symbol will be displayed on the screen Set the alarm limit to OFF to disable the alarm function Press the DN or UP button to change the upper alarm limit and hold it down to quickly increase or decrease the value Press...

Page 8: ...r UP buttons to change the memory serial number the corresponding data will be displayed To exit this mode press the STORE ENTER button to return to the previous mode To delete all data in memory press and hold the ZERO WBT button and UNIT button to delete all stored data and the serial number will return to 01 with 3 beeps Review of parameters related to automatic recording Press the LOG SET butt...

Page 9: ...o move the arrow to INT Press LOG SET to confirm and enter the settings and the last two digits under the display will flash Press the UNIT or STORE ENTER button to change the value S M H indicates second minute and hour respectively Press the LOG SET button to save the current flashing digits Press the DN or UP button to exit this setting without saving and enter other environments Press the HOLD...

Page 10: ... configurable parameters will return to factory settings Press the DN or UP button to exit this setting Press the HOLD button to exit review and adjust mode and return to normal mode Automatic data recording Under normal measurement conditions press the LOG SET button for 2 seconds and the LOG and JOB symbols and data will be displayed on the screen The device will record according to the paramete...

Page 11: ...download data please refer to the user manual The unit will cancel the auto power off function and the APO symbol will disappear After the communication close the program the PC symbol will not disappear and the data recording will stop Disconnect the USB cable from the PC and the PC connection symbol disappears and a new recording can be made After successful connection and data transfer do not w...

Page 12: ... 8000 Automatic screen shutdown 30 seconds no activity Automatic device shutdown 30 minutes no activity PC Interface USB 2 0 Accessories Humidity sonde wire USB y CD Optional accessories Termocouple K type not included Power supply A battery 9V 6F22 6LR61 Intensity of work 25mA Working temperature 0ºC 43ºC Working Humidity 5 95 HR without condensation Storage 30ºC 60ºC 90 HR without battery Dimens...