CS033663DE
ZP-CS01E
TORKEL 900-SERiES
15
4 MENU SYSTEM
The warning and stop limits can be set and changed
during a test.
The settings for the warning and stop levels are inde-
pendent of each other.
See also chapter "7 Alarm function" on page 32
Warning limit
When a "Warning" limit is reached, the "information
bar" turns yellow and the warning cause is displayed.
The alarm buzzer sounds as well.
The warning is confirmed by pressing the "informa-
tion bar" and the alarm buzzer stops to sound.
Stop limit
When a "Stop" criteria is reached, the "information
bar" turns red and the cause of stop is displayed.
Note
This means that the discharge is stopped and
you can change parameters and continue the
test or press
to close the test.
When BVM stop limit is set and a BVM gets
loose during test, the test stops.
Setting the limit parameters
1]
Press the numeric field and make the settings
for the limit parameter using the On-screen
keyboard or using the control knob (press to
confirm).
2]
Enable the limit by touching the checkbox.
3]
Go on with the desired parameters.
Test configuration
1]
Press
ID Labels
2]
Click the label fields and enter the informa-
tion as desired.
Settings
▪
Select
Internal
(prefault) or
External
.
For external current clamp / current shunt set the
Ratio,
see section"6.2 Setting up external current measurement"
on page 28.
▪
if desired enable temperature compensation.
▪
if desired enable cell numbering from plus (default
numbering is from minus).
Temperature compensation
if temperature compensation is enabled, see above, a
button
will be shown in TEST menu.
1]
Press
to make settings for the tempera-
ture compensated test.
2]
Press button to the right to enable
Rate
or
Time
correction.
Summary of Contents for TORKEL 910
Page 2: ......
Page 13: ...CS033663DE ZP CS01E TORKEL 900 series 13 4 Menu system...
Page 27: ...CS033663DE ZP CS01E TORKEL 900 series 27 6 External current measurement...
Page 31: ...CS033663DE ZP CS01E TORKEL 900 series 31 7 Alarm function...
Page 33: ...CS033663DE ZP CS01E TORKEL 900 series 33 8 How to obtain the desired current...
Page 41: ...CS033663DE ZP CS01E TORKEL 900 series 41 10 Troubleshooting...
Page 43: ...CS033663DE ZP CS01E TORKEL 900 series 43 11 Calibration...
Page 45: ...CS033663DE ZP CS01E TORKEL 900 series 45 12 Specifications...
Page 49: ...CS033663DE ZP CS01E TORKEL 900 series 49 12 Specifications...