www.megger.com
DLRO10 and DLRO10X
20
Data
Transfer Real
Time or from storage via RS232
Storage
700 tests
Memo Field
Up to 200 characters per test via integral
alphanumeric keypad.
Battery
Capacity
5.2 Ah Li ion
Life
Typically 1300 x 10 A tests before recharge
Recharge
12 to 15 V d.c. supply
Charging Time
4 hrs for full charge
Temperature
Operation
+5 °C to +45 °C (41 °F to 113 °F) at full specification.
-10 °C to +50 °C (14 °F to 122 °F) at reduced accuracy
Storage
-30 °C to +70 °C (-22 °F to 158 °F)
Calibration
20 °C (68 °F)
Coefficient
<0.01% per °C from 5 °C to 40 °C (<0.006% per °F from 41 °F to 104 °F)
Standard charging
0 °C to +40 °C (32 °F to 104 °F)
Humidity
Max
90% RH @ 40 °C (104 °F) non-condensing
Altitude
Max
2000 m (6562 ft.) to full safety specifications
Safety
In accordance with IEC61010-1 600 V Category III - only when DH6 leads are used
EMC
In accordance with IEC61326-1
Dimensions (HxWxD)
With Battery
245 x 237 x 100 mm (9.6 x 9.3 x 4 inch)
Without Battery
171 x 237 x 100 mm (6.7 x 9.3 x 4 inch)
Weight
With Battery
2.46 kg (5.42 lb)
Without Battery
1.48 kg (3.26 lb)