Specifications
Technical Specifications
For all detailed specifications, the accuracy is given as +/- ([% of reading] + [number of least significant digits]) at
18 ºC to 28 ºC (64°F to 82°F), with relative humidity up to 90 %, for a period of one year after calibration.
Voltage (DC)
Range
AVO830 - 1.0000 V, 10.000 V, 100.00 V, 600.0 V
AVO835 - 1.0000 V, 10.000 V, 100.00 V, 1000.0 V
Accuracy
±0.1% +2
Input resistance
10 MΩ / 10 KΩ
Voltage (AC)
Range
AVO830 - 1.0000 V, 10.000 V, 100.00 V, 600.0 V
AVO835 - 1.0000 V, 10.000 V, 100.00 V, 1000.0 V
Accuracy
45 Hz - 500 Hz
±1.0% +3
500 Hz - 1 kHz
±2.0% +3
1 kHz - 5 kHz
±3.0% +3
Input resistance
10 MΩ / 10 KΩ
Current measurement (DC)
Range
100.00 mA, 1.0000 A, 10.000 A
Accuracy
±1.0% +3
Current measurement (AC)
Range
100.00 mA, 1.0000 A, 10.000 A
Accuracy
45 Hz - 500 Hz
±1.5% +10
500 Hz - 1 kHz
±2.0% +20
Phase rotation
Range
95 V - 440 V
Resistance measurement
Range
100.00 Ω, 1.0000 kΩ, 10.000 kΩ, 100.00 kΩ, 1.0000 MΩ,
10.000 MΩ, 50.00 MΩ
Accuracy
0.1 Ω - 6 MΩ
±1.0% +2
6 MΩ - 50 MΩ
±2.0% +2
Conductance
Range / resolution
1nS - 60.00 nS / 0.01 nS
Accuracy
±1.5% +10
Continuity measurement
Range / resolution
100.00 Ω / 0.01 Ω
Buzzer ON
≤5 Ω
Buzzer Intermittent
>5 <50 Ω
Buzzer off
≥50 Ω
Frequency measurement
Range/resolution
100.00 Hz / 0.01 Hz
1.0000 kHz / 0.0001 kHz
10.000 kHz / 0.001 kHz
100.00 kHz / 0.01 kHz
Accuracy
±0.1% +2