background image

 

 

CAUTION  

PLEASE READ CAREFULLY THE FOLLOWING SAFETY GUIDELINES BEFORE OPERATION 

FOR INSTALLATION, PLEASE READ THIS MANUAL CAREFULLY

 

REPAIRS SHOULD BE DONE BY A QUALIFIED SERVICE PERSON ONLY

 

 

l

  Do not use this appliance indoors, as it may cause personal injury or property damage. 

l

  This outdoor heater is not intended to be installed on recreational vehicles and/or boats. 

l

  Appliance should be located on a solid surface. 

l

  A qualified person should carry out maintenance and repair. 

l

  Improper installation, adjustment, alteration can cause personal injury or property damage. 

l

  Do not attempt to alter the unit in any manner. 

l

  Never  replace  or  substitute  the  regulator  with  any  regulator  other  than  the  factory-suggested 

replacement. 

l

  Do not store or use gasoline or other flammable vapors or liquids in the heater unit. 

l

  The  whole  gas  system,  hose,  regulator,  pilot  or  burner  should  be  inspected  for  leaks  or  damage 

before use, and at least annually by a qualified service person. 

l

  All leak tests should be done with a soap solution. Never use an open flame to check for leaks. 

l

  Do not use the heater until all connections have been leak tested. 

l

  If smell of gas is detected, turn off the gas valve immediately. 

l

  Do not transport heater while it is operating. 

l

  Do not move the heater after it has been turned off until the temperature has cooled down.. 

l

  Control compartment, burner and circulation air passageways of the heater must be kept clean. 

l

  Frequent cleaning may be required as necessary. 

l

  The LP tank should be turned off when the heater is not in use. 

l

  Check the heater immediately if any of the following occurs: 

-    The heater does not reach temperature. 
-    The  burner  makes  popping  noise  during  use  (a  slight  noise  is  normal  when  the  burner  is 

extinguished). 

-    Smell of gas in conjunction with extreme yellow tipping of the burner flames. 

l

  The  LP  Gas  regulator/hose  assembly  must  be  located  in  the  tank  cabinet  where  LPG  cylinder 

located 

l

  Any  guard  or  other  protective  device  removed  for  servicing  the  heater  must  be  replaced  before 

operating the heater. 

l

  Adults  and  children  should  stay  away  from  high  temperature  surface  to  avoid  burns  or  clothing 

ignition. 

l

  Children should be carefully supervised when they are in the area of the heater. 

l

  Clothing or other flammable materials should not be hung on the heater or placed on or near the 

heater. 

 
 
 

 

 

Summary of Contents for MODO FIRE PIT - Y3

Page 1: ...A Permit Number 1185 36 1 RSA 12 A ASSEMBLY OPERATING INSTRUCTIONS Important Read these instructions for use carefully so as to familiarize yourself with the appliance before connecting it to its gas cylinder Keep these instructions for future reference ...

Page 2: ...g Y3 4 Parts list Y3 5 Assembly Procedures 6 Heater Stand and Location 7 Gas Requirements 7 Leakage Test 7 Adjustment to Regulator 7 Back Burn 8 Lighting instructions 8 Cleaning and Care 8 Storage 9 Data badge 10 Problems Check List 11 Warranty 12 ...

Page 3: ...s l Do not use the heater until all connections have been leak tested l If smell of gas is detected turn off the gas valve immediately l Do not transport heater while it is operating l Do not move the heater after it has been turned off until the temperature has cooled down l Control compartment burner and circulation air passageways of the heater must be kept clean l Frequent cleaning may be requ...

Page 4: ...4 ...

Page 5: ...ds 2kg 5 Front panel 1 20 Supporter 1 1 6 Front table 1 21 Hinge 2 7 Top panel 1 22 Supporter 2 1 8 Left panel 1 23 Magnet 2 9 Left table 1 24 Door 1 10 Right table 1 25 Door knob 1 11 Gas valve knob 1 26 Door stopper 1 12 Burner bracket 1 27 Supporter 3 1 13 Burner bottom piece 1 28 Door frame 1 14 Burner top piece 1 29 Gas valve 1 15 ODS Pilot bracket 1 30 Gas valve bracket 1 ...

Page 6: ...w below procedures Step 1 Fix each wheel with 4xM6 screws Step 2 Then fix right table piece and left Table piece with 12xM6 screws Step 3 1 Fix the front table piece with 6xM6 Screws 2 Then fix the right and left to front With 8xM6 screws 3 Last fix 2xM6 screws from front Table piece bottom ...

Page 7: ...ous and should be checked by your cylinder supplier Never use a LP Gas cylinder with a damaged valve connection l The LP Gas cylinder must be arranged to provide for vapor withdrawal from the operating cylinder l Never connect an unregulated LP Gas cylinder to the heater LEAKAGE TEST Gas connections on the heater are leak tested at the factory prior to shipment A complete gas tightness check must ...

Page 8: ...trol knob pressed for 5 seconds then release it 5 If the burner does not stay alight repeat steps 3 and 4 If the burner has not lit wait 5 minutes and repeat steps 3 and 4 6 Adjust the heat setting by turning the control knob to the high or low position 7 To turn the heater OFF turn the cylinder valve or regulator switch to the OFF position and then turn the control knob on the appliance clockwise...

Page 9: ... the surface of the burner 4 The patio heater is making a popping noise 5 The flame flashes back into the burner tube and make a loud roaring noise Repairing and Service Examine all fixtures and tighten where needed check for gas leaks using a solution of soapy water and spray on appropriate joints Should you wish to service the patio heater take it to a qualified person or company STORAGE 1 Alway...

Page 10: ...VENTILATED AREAS THIS APPLIANCE IS NOT FOR DOMESTIC USE WARNING ACCESSIBLE PARTS MAY BE VERY HOT KEEP YOUNG CHILDREN AWAY READ THE INSTRUCTION LITERATURE BEFORE USING THE APPLIANCE THE APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH THE INSTRUCTIONS AND LOCAL REGULATIONS CLOSE THE VALVE OF THE GAS CYLINDER OR THE REGULATOR AFTER USE THE USE OF THIS APPLIANCE IN ENCLOSED AREAS CAN BE DANGEROUS AND I...

Page 11: ...11 ...

Page 12: ...ng it back to the retailer This enables Megamaster to process your inquiry quickly SERVICE NUMBER 27 12 802 1515 This product is intended for use with a 9kg LP Gas Cylinder use of any other cylinder any resulting damage to the product will void the warranty This product is intended for use with the supplied low pressure 2 8kPa LP gas regulator use with any other type of pressure regulator and any ...

Page 13: ...China Distributed by Megamaster PO Box 15 Woodlands 0027 South Africa Tel 27 0 12 802 1515 WARNING Read and follow all Safety Assembly and Use Care Instructions in this guide before assembling and using this product Failure to follow all instructions in this Use Care Guide may lead to fire or explosion which could result in property damage personal injury or death ...