background image

1.

 

IMPORTANT: 

Turn off the mains electrical supply.

2.

 

Ensure that the wall (back) box has a minimum depth of 35mm.

3.

 

Remove and disconnect the existing light switch (if applicable). It may be 

useful at this point to mark out or take a photograph of the connections to 
the existing switch so that the correct wires can easily be transferred to the 
new Dimmer. Some existing wiring configurations can be complex so take 
care. 

4.

 

Gently remove Dimmer faceplate by inserting a screwdriver into the 

bottom slot/s and lifting away from the unit as shown.

Installation

Summary of Contents for lightwaveRF Connect Series

Page 1: ...lightwaveRF Connect Series Dimmer 2 Way Dimmer Model No JSJSLW455 Instruction Manual www megamanuk com lightwaverf...

Page 2: ......

Page 3: ...guide you through the installation process Help Video You can scan this QR code with your smartphone It will take you to a video that will help guide you through setup and installation To install the...

Page 4: ...ts and other LightwaveRF Controllers For additional guidance please visit www megamanuk com lightwaverf Amber LED When illuminated Dimmer is off On Button Hold to raise light level Off Button Hold to...

Page 5: ...o switch the Dimmer on Blue LED indicator will illuminate Press and hold the on button to raise the light level Tap either off bottom button once to switch the Dimmer off Amber LED indicator will illu...

Page 6: ...instructions Failure to do so may void your warranty LightwaveRF is fully legal to install in your own home However if in doubt always consult a qualified electrician Installation Switched live live o...

Page 7: ...wired as a standalone dimmer OR be connected to other LightwaveRF 2 Way Dimmers to perform 2 Way switching The wiring diagram on the following pages illustrates how this gang should be wired The 2 Way...

Page 8: ...ected directly to the standard Dimmer or connected to each other in a daisy chain This provides an alternative to using intermediate switches maximum cable length of 100m VERY IMPORTANT A LightwaveRF...

Page 9: ...t may be useful at this point to mark out or take a photograph of the connections to the existing switch so that the correct wires can easily be transferred to the new Dimmer Some existing wiring conf...

Page 10: ...e connected it only requires live in switched live out and a signal connection 7 Screw the Dimmer Switch to the mounting box and ensure that the screws are sufficiently tight to support the product bu...

Page 11: ...ains Earth wire connects to terminal in back box can be capped off instead if no terminal present Live Wire In This should be Brown or Red in Colour Switched Live Wire Out This should be blue or black...

Page 12: ...e input marked S must ONLY be connected to the wire running to the other Dimmer NOT live mains this will cause irreparable damage 3 Core Cable From Lighting Circuit Live Live Earth Switched Live Signa...

Page 13: ...he Dimmers are used solely to switch between the on and off states without dimming This is because the technology used in an electronic dimmer is fundamentally different to that of a simple on off swi...

Page 14: ...gen low energy incandescent lighting min 20W max 250W GU10 and equivalent HI spot mains halogen lamps Dimmable Electronic Low Voltage Transformers 20W 250W max Inductive Transformers 40 170VA max Sele...

Page 15: ...rminals a common mistake is to reverse the live and switched live connections Remember the signal terminal must NOT be connected to 230V mains If these measures fail contact technical support via www...

Page 16: ...om the corresponding standard LightwaveRF Dimmer via the connected signal wire The standard LightwaveRF Dimmer gang incorporates an RF module and can be linked to a controller Problem The Dimmer keeps...

Page 17: ...es LightwaveRF is fully legal for you to install in your own home Q Is there a maximum number of lamps I can control with the Dimmer A You can control any number of lamps bulbs as long as they do not...

Page 18: ...mers are not designed to have their switch modules separated and interchanged disconnecting and removing Dimmer Modules will invalidate the warranty Q What Happens after a power cut A Standard Lightwa...

Page 19: ...3W 250W max Incandescent Load 20W min 250W max 2 Way Gang Input rating 220 240V 50Hz Back Box Depth 35mm min Earthing Requirement Not essential double insulated Standby Energy Use Less than 1W per gan...

Page 20: ...www megamanuk com lightwaverf lightwaveRF 2 Quadrant Park Mundells Welwyn Garden City Herts AL7 1FS 01707 386035...