MegaLite Ribbon 4371 User Manual Download Page 9

Main Control Menu 

The control board on the fixture base is your interface to 
access and control all the functions on the unit.  Its Dip 
Switch gives you a code view of the options.  The following 
will explain each function and its options. 

DMX 512 IN 

DMX 512 OUT 

GND 

DATA — 

DATA + 

001

 

002

 

004

 

008

 

016

 

032

 

064

 

128

 

256

 

FU

N

 

1  2  3  4  5  6  7  8  9 10 

001

 

002

 

004

 

008

 

016

 

032

 

064

 

128

 

256

 

FUN

 

5  6 

9

 

10 

ON 

DMX Addressing 

DMX signal cable must be connected in order to respond to DMX mode. 
 
Turn dipswitch 10 to the 

OFF 

position.  Each dipswitch from 1 to 9 holds a 

numerical value located below the dipswitch.  Add the numerical value to 
get the desired fixture start address channel.  The user must assign a 
start address on the fixture that indicates the first channel reserved in the  
controller. 
 
For example, if you wish the first unit to start on address channel 85 you 
will need to turn on dipswitch 1,3,5 and 7 (1+4+16+64=85) 
 

001

 

002

 

004

 

008

 

016

 

032

 

064

 

128

 

256

 

FUN

 

5  6 

9

 

10 

ON 

Functions 

FUNCTION 

10 

RED 

ON 

  

  

  

  

  

  

  

  

  

GREEN 

  

ON 

  

  

  

  

  

  

  

  

BLUE 

  

  

ON 

  

  

  

  

  

  

  

YELLOW 

  

  

  

ON 

  

  

  

  

  

  

PURPLE 

  

  

  

  

ON 

  

  

  

  

  

CYAN 

  

  

  

  

  

ON 

  

  

  

  

WHITE 

  

  

  

  

  

  

ON 

  

  

  

COLOR SNAP 

SPEED 1  SPEED 2  SPEED 3  SPEED 4  SPEED 5  SPEED 6  SPEED 7 

ON 

  

  

COLOR FADE 

SPEED 1  SPEED 2  SPEED 3  SPEED 4  SPEED 5  SPEED 6  SPEED 7 

  

ON 

  

FUN

CTION 

RED 

GREEN 

BLUE  YELLOW  PURPLE  CYAN 

WHITE  COLOR S  COLOR F 

ON 

Turn dipswitch 10 to the 

ON 

position.  This function will turn on the func-

tions that will allow the unit to run a preprogram function.  Additionally, this 
unit may serve as a master unit where other units will copy it’s functions.  
To create a master unit connect the XLR cable from the output to the in-
put on the next unit.  

Summary of Contents for Ribbon 4371

Page 1: ...MANUAL Table of Contents Safety Information 3 Specifications 4 Main Power Connection 6 DMX 512 Connection 6 Installation 7 Rigging the Fixture 8 Main Control Menu 9 DMX Profile 10 Cleaning Maintenanc...

Page 2: ......

Page 3: ...vement 6 Maximum surface operating temperature 80 Protection Against Fire 1 Disconnect power before servicing 2 For connection to main power supply proceed to page 5 3 This unit must be earthed electr...

Page 4: ...Power 5V 90W 12V 220W 24V 450W Brightness Control 256 Scales Protocol DMX 512 1990 DMX Channels 3 Control options Built in functions Control Programming 4 95 2 65 1 65 4 4371 Color Ribbon 24V Specifi...

Page 5: ...x 1 55 H Weight 4 lbs Size 6 L x 3 W x 3 5 H Weight 1 4 lbs Connectors Removable phoenix connectors Power Connection External power supply bare cable Fastening System 2 fixture mounting points Electri...

Page 6: ...r cable designed for RS 485 and 3 pin XLR plugs and connectors in order to connect the controller with the fixture or the fixture with another DMX input DMX output 1 Shield 2 Signal 3 Signal Caution A...

Page 7: ...power up to 16 4 of Color Ribbon 16 4 B R G B R G B R G 16 4 B R G B R G B R G DMX Output DMX Output DMX Input DMX Output DMX Input DMX Controller Power Supply Power Supply Installing using Color Rib...

Page 8: ...If you lack these qualifica tions do not attempt the installation yourself instead use a professional structural rigger Unit Ships with 10 braces per ribbon reel These braces should be used to secure...

Page 9: ...address on the fixture that indicates the first channel reserved in the controller For example if you wish the first unit to start on address channel 85 you will need to turn on dipswitch 1 3 5 and 7...

Page 10: ...l allow you to test the intensity of each color or to set the color ribbon to a specific color FUNCTION 1 2 3 4 5 6 7 8 9 10 RED 33 RED 33 RED 33 GREEN 33 GREEN 33 GREEN 33 BLUE 33 BLUE 33 BLUE 33 FUN...

Page 11: ...on spot and usage have to be adhered by a skilled installer and any safety problems have to be removed Disconnect from mains before starting maintenance operation Caution Danger to life We recommend a...

Page 12: ...Mega Lite 5718 Kenwick St San Antonio TX 78238 Ph 210 684 2600 Fax 210 855 6279 www mega lite com info mega lite com...