Caution!

1. The Installation must be carried out by an authorized dealer or trained professional.
2. Unit may cause severe injures, if you have doubts concerning the safety do not install.
3. Unit is to be 24 inches away from flammable materials. 
4. Use high quality installation equipment to hang the unit.
5. Internal Fan Filters must be cleaned periodically as not to block airflow.

When rigging the it is very important that you follow common safety procedures. Rigging requires extensive 
experience including but not limited to calculating working weight loads, material being used and periodic safety 
inspections. If you lack these qualifications, do not attempt the installation yourself, instead use a professional 
structural rigger.

When rigging the unit always be secure with a secondary safety attachment.  The installation location of the 
fixture has got to be built in the way that it can hold 10 times the weight for 1 hour with out any failures.  Instal-
lation should be checked at least one time a year by a skilled professional.

Cleaning and Maintenance

Installation Maintenance- The operator has to make sure that the unit is operating safely and has the installations and electronics 
checked by an expert every year.

The following points must be considered during the inspection:
1)All screws used for installing the device or part of the device have to be tightly connected and must not be corroded.
2) There must not be any deformations on the housing, fixation and installation spots (ceiling, suspension, trussing).
3) The electronic power supply cables must not show any damages, material fatigue (e.g. porous cables) or sediments. Further   
instructions depending on the installation spot and usage have to be adhered by a skilled installer and any safety problems have to be 
removed.
4) Fixture housing must only be cleaned from the outside using only soap and water.
5) Internal fan filters but be cleaned periodically 

Note:

 Maintenance and service operations are to be carried out by authorized dealers.

Replacing the fuse: 

When possible, only replace the fuse with the same type and rating.

Replacing the power cable:

 If the power cable of this device becomes damaged, it has to be replaced by authorized dealers or 

trained professionals only.

Should you have further questions, please contact your dealer.

Fixture should not be installed in location were temperature will reach 113

°F

 

or colder than 23

°F.

 

Summary of Contents for Framebot 600

Page 1: ...f Contents Safety Information 2 What s Included 2 Specifications 3 Gobos Colormation 4 Colors 5 Main Power Connection 6 Installation 7 Cleaning Maintenance 7 DMX Profile 11 Size Weight 13 Warranty 14...

Page 2: ...ing 2 For connection to main power supply proceed to page 4 3 The power supply must be earthed electronically grounded 4 This fixture must not be left on for long periods of time 1 Use secondary safet...

Page 3: ...Light Source 580W White LED Color Temp WW 6408K CRI Warm White 70 Color Flags Cyan Magenta Yellow Kelvin CMYK Color Wheel 6 Color Bi direction Rotating Gobo s 6 Indexing Bi directional Changeable Gobo...

Page 4: ...Gobo s Rotating Gobo s Size 27 9mm Image 22mm Thickness Max 2 2mm 1 2 3 4 5 6 7 8 1 2 3 6 4 5 Static Gobo s Colormation 4 TM...

Page 5: ...Colors Color Mixing Cyan Magenta Yellow Kelvin Color Wheel Open 1 Red 2 Yellow 3 Green 4 Blue 5 Orange 6 Dark Blue 5...

Page 6: ...connection The sockets are wired in parallel Only use a shielded twisted pair cable designed for RS 485 and 3 or 5 pin XLR plugs and connectors in order to connect the controller with the fixture or t...

Page 7: ...ator has to make sure that the unit is operating safely and has the installations and electronics checked by an expert every year The following points must be considered during the inspection 1 All sc...

Page 8: ...dress from 001 to 473 using the up down buttons Press Enter to confirm or Mode to go back The fixtures start address will need to match the DMX Controllers assigned DMX start channel i i ADDRESS RUNTI...

Page 9: ...temperature recommended PERFORMANCE Fan speed will stay at he highest level to maintain fixtures performance level QUIET Fixtures lamp output will be reduced to adjust to fixtures safe operating temp...

Page 10: ...SE DISPLAY Display Orientation ON Display will remain base to the bottom view OFF Display will invert to base on top view Auto Display will automatically invert depending base s position i SETTING LOC...

Page 11: ...to full 0 255 0 Open 0 7 Gobo 1 8 15 Gobo 2 16 23 Gobo 3 24 31 Gobo 4 32 39 10 Static Gobo Gobo 5 40 47 0 Gobo 6 48 55 Gobo 7 56 63 Gobo 8 64 71 Gobo By Position 72 143 Counter Clockwise Rotation Fast...

Page 12: ...9 0 Frost clear to frost 10 255 25 Colormation No Function 0 7 0 Colormation Engage linear 8 255 No Function 0 7 26 Colormation Counter Clockwise Rotation Fast to Slow 8 127 0 Rotation Stop 128 135 R...

Page 13: ...Fixture Size Fixture Weight Packaged Size Packaged Weight 15 33 X 13 33 X 25 56lb 30 5 X 18 5 X 21 5 66lb Size and Weight 14 15 33 13 33 21 13 14 13 2 12 2 12 11 09 17 5 7 5 4 54 3 87 25 11 75...

Page 14: ...year 3 Parts and Labor 730 days two years 4 Parts and Labor 1095 days three years This limited warranty excludes any defects caused by resulting from or relating to the following Normal wear and tear...

Page 15: ...line to provide set up help and to answer any questions should you encounter a problem Please visit our website for any other related technical documents For service related issues please contact our...

Reviews: