7
Installation
Caution!
1. The Installation must be carried out by an authorized dealer or trained professional.
2. Unit may cause severe injures, if you have doubts concerning the safety do not install.
3. Unit is to be 24 inches away from flammable materials.
4. Use high quality installation equipment to hang the unit.
5. Internal Fan Filters must be cleaned periodically as not to block airflow.
When rigging the it is very important that you follow common safety procedures. Rigging requires extensive
experience including but not limited to calculating working weight loads, material being used and periodic safety
inspections. If you lack these qualifications, do not attempt the installation yourself, instead use a professional
structural rigger.
When rigging the unit always be secure with a secondary safety attachment. The installation location of the
fixture has got to be built in the way that it can hold 10 times the weight for 1 hour with out any failures. Instal-
lation should be checked at least one time a year by a skilled professional.
Cleaning and Maintenance
Installation Maintenance- The operator has to make sure that the unit is operating safely and has the installations and electronics
checked by an expert every year.
The following points must be considered during the inspection:
1)All screws used for installing the device or part of the device have to be tightly connected and must not be corroded.
2) There must not be any deformations on the housing, fixation and installation spots (ceiling, suspension, trussing).
3) The electronic power supply cables must not show any damages, material fatigue (e.g. porous cables) or sediments. Further
instructions depending on the installation spot and usage have to be adhered by a skilled installer and any safety problems have to be
removed.
4) Fixture housing must only be cleaned from the outside using only soap and water.
5) Internal fan filters but be cleaned periodically
Note:
Maintenance and service operations are to be carried out by authorized dealers.
Replacing the fuse:
When possible, only replace the fuse with the same type and rating.
Replacing the power cable:
If the power cable of this device becomes damaged, it has to be replaced by authorized dealers or
trained professionals only.
Should you have further questions, please contact your dealer.
Fixture should not be installed in location were temperature will reach 113
°F
or colder than 23