2.5 

Professional Installation Instructions 

Safety and Regulatory Compliance Information 

This  document  contains  important  safety  and  regulatory  compliance  information  for  the 

following products: 

 

Please read this document before installing and using your product and see the following 

sections for more information: 

• Safety Information   

• Federal Communications Commission (FCC) Compliance 

– Modifications 

– Warnings 

• Information for Professional Installers 

• Regulatory Compliance Certifications Summary 

 

Safety Information 

All  products  are  intended  to  be  installed,  used,  and  maintained  by  experienced 

telecommunications personnel only. 

When using this device, basic safety precautions should always be followed to reduce the 

risk of fire, electrical shock, and injury to persons, including the following: 

•  Operate  and  install  these  products  as  described  in  this  manual.  Equipment  must  be 

installed and used in strict accordance with the manufacturer's instructions as described in 

the user documentation provided. 

•  Installation  of  these  products  in  the  end  use  must  conform  to  local  regulations  and 

codes. 

• Products are to be used with and powered by only the power injector provided. 

• A 13-amp circuit breaker is required at the power source. 

• Do not connect or disconnect the power cable to the equipment when the power injector 

is plugged into an AC power outlet. 

•  Servicing  of  these  products  should  be  performed  only  by  trained  personnel.    Do  not 

disassemble. By opening or removing any covers, you may expose yourself to hazardous 

energy  parts.  Incorrect  reassembly  of  these  products  can  cause  a  malfunction  and/or 

electric shock when the units are subsequently used. No user serviceable parts; all repairs 

and service must be handled by a qualified service center. 

• Do not insert any objects of any shape or size inside these products while powered on. 

Object may contact hazardous energy parts that could result in a risk of fire or personal 

injury. 

• Do not remove or alter the Marking label provided on these products. 

• To avoid the risk of  electric shock from lightning, do not use these products during an 

electrical storm. 

• When using these products with an external antenna, see the installation documentation 

provided with the antenna system. 

 

Summary of Contents for megascan M1

Page 1: ...d on 28th August 2009 Technical Contacts and Enquiry sales scanmega com Website www scanmega com This user manual product specification is subjected to be changed without prior notice P 1 megascan M1...

Page 2: ...ct Features 8 1 6 Specification 9 Chapter 2 Installation of megascan M1 10 2 1 Power up megascan M1 10 2 2 Environmental Requirements 10 2 3 Start up Procedures 11 2 4 Caution 11 2 5 Professional Inst...

Page 3: ...15 certification It is the responsibility of the operator and professional installer to ensure that only certified systems are deployed in the United States The use of the system in any other combinat...

Page 4: ...processing speed and ample memory is an UHF RFID reader which includes powerful RFID reader with 17 RFID antenna ports which operates in 860MHz to 930MHz UHF band and is compliance with ISO 18000 6C...

Page 5: ...notice P 5 1 2 Ports Description The megascan M1 has several types of input output port Items Name Description 1 Ethernet Port RJ 45 10BaseTx 100BaseTx port that connects the reader to your Ethernet n...

Page 6: ...e P 6 1 3 Indicators LEDs in megascan M1 The megascan M1 has different LEDs to indicate the reader status Name Label Description LAN Status 10BaseTx 10M Turn ON when 10Mbps network detected LAN Status...

Page 7: ...and Enquiry sales scanmega com Website www scanmega com This user manual product specification is subjected to be changed without prior notice P 7 1 4 Antenna for megascan M1 There is no antenna shipp...

Page 8: ...tivity Consistently supports read ranges up to 30 feet Dense Reader Mode DRM Capability Power over Ethernet PoE connectivity Low power consumption Adjustable output Tx power levels over 5 to 30dBm ran...

Page 9: ...MHz ETSI 865 868 MHz NCC 922 928 MHz SRRC 920 925 MHz RF Output Power Adjustable from 5 to 30dBm in 1 dB steps Supply Voltage Power over Ethernet PoE IEEE standard 802 3af compliant Power Consumption...

Page 10: ...connect with Cat 5 and higher infrastructure cable Antenna port is standard SMA Jack female the RF cable antenna connector should be standard SMA Plug male megascan M1 operates at UHF frequency band r...

Page 11: ...s connected an UHF antenna before turn on the RF power for testing Caution Each port must have either an antenna or a terminator connected Do not apply power to the megascan M1 unless an antenna or te...

Page 12: ...rict accordance with the manufacturer s instructions as described in the user documentation provided Installation of these products in the end use must conform to local regulations and codes Products...

Page 13: ...its Warnings Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment The equipment has been tested...

Page 14: ...or authorization to use this device prior to turning on the equipment Modifications The FCC requires the user to be notified that any changes or modifications to this device that are not expressly app...

Page 15: ...cation with megascan M1 Megabyte Ltd megascan M1 is an intelligent reader and compliance with EPC global C1G2 ISO 18000 6C Users can develop own UHF RFID application on this platform 3 1 1 Delivering...

Page 16: ...turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation...

Page 17: ...tain compliance with the power density limit The minimum required cable length is 1 5m to be used with this device The following formula was used to calculate the Power Density S Where S Power Density...

Page 18: ...Marking The CE Mark is a conformity marking consisting of the letters CE The CE Mark applies to products regulated by certain European health safety and environmental protection legislation The CE Mar...

Page 19: ...tion with the furnishing performance or use of this material This document contains proprietary information which is protected by international patent applications and copyright All rights reserved No...

Page 20: ...bserve this User Manual and the instructions accompanying the Products or any alterations maintenance or repair to the Products by any person other than Megabyte Ltd use of non Megabyte Ltd parts acce...

Page 21: ...tacts and Enquiry sales scanmega com Website www scanmega com This user manual product specification is subjected to be changed without prior notice P 21 Chapter 7 Support Technical support sales enqu...

Reviews: