5
Main Power Connection
Caution!
1. Do not connect fixture to a dimmer system.
2. This unit must be earthed. (electronically grounded)
3. Replace fuse only with the specified type and rating.(15Amp 250V, 20mm)
The occupation of the connection-cable is as follows:
DMX-512 Connection
The fixture is equipped with 3 and 5 pin XLR Sockets for DMX input and output. The sockets are wired in parallel. Only
use a shielded twisted pair cable designed for RS-485 3 and 5 pin XLR plugs and connectors in order to connect the
controller with the fixture or the fixture with another.
Caution!
At the last fixture the DMX signal needs to be terminated with a terminator. Solder a
120 Ohm resistor between the (-) and the (+) signal into a 3 or 5 pin XLR plug and
plug it in to the last fixture on the signal run. Pre-manufactured terminator plugs are
available for purchase from your Mega-FX dealer (P-DMX-T).
Cable (USA)
Cable (EU)
Pin
110V
Black
Brown
White
Green
Light Blue
Yellow/Green
Live
Neutral
Ground
L
N
DMX—input
DMX—output
1. Shield
2. Signal (-)
3. Signal (+)
5
3
4
2
1
1
2
3
4
5
4. N/A
5. N/A
2
3
1
1
2
3
L
N
Summary of Contents for H5 Hazer