B. Re-zeroing knob "a" & "b" on the amplifying valve:
For zeroing knob "a", there is a hydraulic pressure gauge as drawing <S> needed, Please plug it
onto the outlet on the amplifying valve.
Pressure read at line <p> as the primary pressure............pressure <p>
Pressure read at amplifying valve as the secondary pressure.. pressure <s>
The primary pressure should be kept the same reading, and the secondary pressure can be adjusted
by turning knob "b" for cutting pressure settings zeroing knob "a" :
------------------
Dry run the machine as stated in above paragraph,
Turn knob "b" while reading pressure <s>, If there is any pressure can be read, then turn knob "a"
While watching saw frame, if the saw frame shall stand still there without coming down, then there is
the zero position of the knob "a" ( zero feed-rate ), check the "
△
" mark on the knob "a" to see if
this mark pointing to "0" position. If not, loosen set screw and zeroing it ( Please make sure tighten
the set screw after zeroing ). zeroing knob "b" :
------------------
After zeroing knob "a", turn knob "a" at "5" position, and let the machine running in the same
condition as previous did - dry running. turn knob "b" while reading pressure <s>, If the pressure
reach 5.5 to 6 kg /sq.cm, then loosen the set screw on the knob "b" and have the "
△
" mark
pointing to "5" position and tighten the set screw.
(3.) OPERATION
Knob "a" is for maximum feed-rate setting:
The smaller the diameter of the material being cut, the higher feed-rate.
The softer the material being cut, the higher feed-rate can be set. And vice-versa.
Knob "b" is for cutting pressure setting:
The tougher the material being cut, the hiher cutting pressure needed. For instance, when cutting
thin pipes/tubes, mild carbon steels, Only little pressure needed, and for stainless/high alloy tool
steels or inconel special steels, high cutting pressure should be needed. There are both AISI/JIS
material codes shown on the control panel, Please refer to it for proper cutting pressure setting.
LIMITATION:
The sum of the number set on knob "a" and "b" can not exceed 10.