Cleaning and maintenance 

Installation 

M

aintenance: 

The operator has to make sure that the unit is operating safely and has the installations and electron-

ics checked by an expert every 2 years. 
 
The following points have to be considered during the inspection: 
1)  All screws used for installing the device or part of the device have to be tightly connected and must not be corroded. 
2)  There must not be any deformations on the housing, fixation and installation spots (ceiling, suspension, trussing). 
3)  The electronic power supply cables must not show any damages, material fatigue (e.g. porous cables) or sediments.  Further 

instructions depending on the installation spot and usage have to be adhered by a skilled installer and any safety problems 
have to be removed. 

Note: 

There is no serviceable parts inside the device except for the LED’s.  Maintenance and service operations are to be carried 

out by authorized dealers. 

Replacing the fuse:  

Only replace the fuse with the same type and rating. 

Replacing the power cable:  

If the power cable of this device becomes damaged, it has to be replaced by authorized dealers or 

trained professional only. 

Should you have further questions , please contact your dealer. 

10 

Parts List 

4075-PCBMA 

Main PCB card 

4075-PS 

Power Supply 

4075-DIS 

Display 

4070-FH 

Fuse Holder 

4075-FAN 

Replacement fan 

Rigging the fixture 

Caution!   

1.  The installations must be carried out by an authorized dealer or trained professional. 
2.  Unit may cause severe injures if you have doubts concerning the safety do not install. 
3.  Unit is to be 24inches away from flammable materials (decoration material) 
4.  Use high quality installation equipment to hang unit. 

When rigging a unit it is very important that you follow common safety procedures.  Rigging requires extensive experience includ-
ing but not limited to calculating working loads, material being used and periodic safety inspections.  If you lack these qualifica-
tions, do not attempt the installation yourself, instead use a professional structural rigger. 
 
When rigging the unit always be secured with a secondary safety attachment.  The installation location of the projector has got to 
be built in the way that it can hold 10 times the weight for 1 hour with out any harming.  Installation should be  checked at least 
one time a year by a skilled person. 

4070-TRILED 

Tri Chip LED 

4075-KNOB 

Knob Set 

Summary of Contents for N-E Color FX9

Page 1: ...SER MANUAL Table of Contents Safety Information 3 Specifications 4 Main Power Connection 5 DMX 512 Connection 5 DMX Profile 6 Main Control Menu 7 Rigging the Fixture 9 Cleaning Maintenance 9 Parts List 9 ...

Page 2: ......

Page 3: ...perly secured away from unit movement 6 Maximum surface operating temperature 80º Protection Against Fire 1 Disconnect power before servicing 2 For connection to main power supply proceed to page 5 3 This unit must be earthed electronically grounded 4 Do not expose unit to rain or moisture Protection Against Mechanical Hazards 1 Use safety chain when hanging unit 2 Use quality clamps or bolts when...

Page 4: ...ng Yoke Electrical Specifications LED Quantity 9 x Tri Color Red 9 Green 9 Blue 9 LED Watts 3 LED refresh rate 4 7k HZ flicker free LED Lifetime 60 000 to 100 000 hours LED Angle 25 Power Consumption Universal 100 240V 50 60 Hz Ballast Electronic Watts 62 Amps 87 Protocol DMX 512 DMX Channels 4 Modes of operation Mode A 3 Channel R G B Mode P 6 Channel R G B Strobe Macro Dimmer Mode F 27 Channel R...

Page 5: ...t The sockets are wired in parallel Only use a shielded twisted pair cable designed for RS 485 and 3 pin XLR plugs and connectors in order to connect the controller with the fixture or the fixture with another Caution At the last fixture the DMX signal needs to be terminated with a terminator Solder a 120 Ohm resistor between the and the signal into a 3 pin XLR plug and plug it in to the last fixt...

Page 6: ... Strobe Strobe slow to fast 0 196 Random Strobe slow to fast 197 255 No Function 0 1 Color fade Full Bar slow to fast 2 19 Color Snap Full Bar slow to fast 20 39 Random Full Bar slow to fast 40 59 Red Chase Each slow to fast 60 79 Green Chase Each slow to fast 80 99 5 Macro Blue Chase Each slow to fast 100 119 White Chase Each slow to fast 120 139 Macro Effect 1 140 159 Macro Effect 2 160 179 Macr...

Page 7: ...ity 0 255 27 LED Color Blue LED Intensity 0 255 N E Color FX9 Mode L DMX Chanel Function Description Value 1 Strobe No Function 0 9 Strobe slow to fast 10 255 2 LED Color Red LED intensity 0 255 3 LED Color Green LED Intensity 0 255 4 LED Color Blue LED Intensity 0 255 33 Strobe No Function 0 9 Strobe slow to fast 10 255 34 LED Color Red LED intensity 0 255 35 LED Color Green LED Intensity 0 255 3...

Page 8: ...Dimmer Flash Fade Scroll Flash Scroll Chase Effect Chase Speed 1 512 0 15 0 15 0 15 0 15 0 15 0 15 0 15 0 15 Mode A 3 Channels R G B Mode P 6 Channels R G B Strobe Macro Dimmer Mode F 27 Channels R G B x 9 Green Dimmer This function allows you to dim the green LED s on the whole module Press Enter use the up down keys to select desired dim mer settings Press Enter to confirm the settings 15 Steps ...

Page 9: ...rm the settings 15 Steps Chase Effect This function allows you to select different chase patterns on the whole module Press Enter use the up down keys to select desired chase settings Press Enter to confirm the settings Chase Speed This function allows you to select the speed of the chase that was selected on the Chase Effect Press Enter use the up down keys to select desired chase speed settings ...

Page 10: ...e replaced by authorized dealers or trained professional only Should you have further questions please contact your dealer 10 Parts List 4075 PCBMA Main PCB card 4075 PS Power Supply 4075 DIS Display 4070 FH Fuse Holder 4075 FAN Replacement fan Rigging the fixture Caution 1 The installations must be carried out by an authorized dealer or trained professional 2 Unit may cause severe injures if you ...

Page 11: ...ged problem or malfunction Ship returned Prod uct units or parts to 5711 Kenwick St San Antonio TX 78254 USA Note Freight Damage Claims are invalid for fixtures shipped in non factory boxes and packing materials Freight All shipping will be paid by the purchaser Items under warranty shall have return shipping paid by the manufacturer only in the Continental United States Under no circumstances wil...

Reviews: