5

 

Main Power Connection

 

Caution!

   

1.

   

Do not connect fixture to a dimmer system.

 

2.

   

This unit must be earthed. (electronically grounded) 

 

3.

   

Replace fuse only with the specified type and rating.

 

The occupation of the connection

-

cable is as follows:

 

Cable (USA)

 

Cable (EU)

 

Pin

 

International

 

Black

 

Brown

 

White

 

Yellow / Green

 

Blue

 

Yellow/Green

 

Live

 

Neutral

 

Pin

 

L

 

N

 

 

1

 

2

 

3

 

1

 

3

 

2

 

DMX

-

512 Connection

 

DMX

input

 

DMX

output

 

1.  Shield

 

2.  Signal (

-

)

 

3.  Signal (+)

 

Caution!

 

On the last fixture the DMX signal needs to be terminated with a terminator. Solder a 120 

Ohm resistor between the (

-

) and the (+) signal into a 3 pin XLR plug and plug it in to the 

last fixture on the signal run.  Pre

-

manufactured terminator plugs are available for 

 

purchase from your Mega

-

Lite dealer (HOS

-

DMXT).

 

AC 100V 50Hz

-

60Hz

 

The fixture is equipped with 3 pin XLR Sockets for DMX input and output.  The sockets are wired in parallel.  Only use a shielde

twisted pair cable designed for RS

-

485 and 3 pin XLR plugs and connectors in order to connect the controller with the fixture or

 

the fixture with another.

 