5
Main Power Connection
Caution!
1.
Do not connect fixture to a dimmer system.
2.
This unit has Auto switching power supply. It will respond to 110V or 220V automatically
3.
This unit must be earthed. (electronically grounded)
4.
Replace fuse only with the specified type and rating.
The occupation of the connection-cable is as follows:
DMX-512 Connection
This fixture is equipped with an electronic power supply that will let the unit operate from 100V to 240V from 50Hz to
If you purchased Model 7051 or 7053 there was a DMX controller included in your packaging this will be your DMX inter-
face device used to control the fixture via DMX controller. If you did not purchase the DMX controller then this fixture will
only turn off and on using the switch on the rear of the fixture. The 7051 and 7053 fixture is equipped with 3 or 5 pin XLR
Sockets for DMX input and output you must specify when ordering that type of connection you require. The sockets are
wired in parallel. Only use a shielded twisted pair cable designed for RS-485 and 3 or 5 pin XLR plugs and connectors
in order to connect the controller with the fixture or the fixture with another.
Caution!
At the last fixture the DMX signal needs to be terminated with a terminator. Solder a 120 Ohm re-
sistor between the (-) and the (+) signal into a 3 pin XLR plug and plug it in to the last fixture on the
signal run. Pre-manufactured terminator plugs are available for purchase from your Mega-Lite
dealer (P-DMXT).
Cable (USA)
Cable (EU)
Pin
110V
Black
Brown
White
Green
Light Blue
Yellow/Green
Live
Neutral
Ground
L
N
220V
L
L
L
N
110V—Connection
L
L
220V—Connection
1
2
3
2
3
1
DMX—input
DMX—output
1. Shield
2. Signal (-)
3. Signal (+)
5
3
4
2
1
1
2
3
4
5
4. N/A
5. N/A