MEFE—Mitchell Engineering Food Equipment Pty Ltd
23 Storie Street Clontarf QLD 4019 Australia
www.mefe.com.au | [email protected]
Page 5
+617 3283 4536
Free AU 1800 669 006
3.2
Regular Function Continued
The water temperature is controlled by a thermostat. This thermostat is set to 85° C. Moreover, the thermostat comes
equipped with a temperature limit controller which functions as a dry
-
run protection appliance. If the heater element is
heating although there is no water in the basin, the heater element is shut off automatically when reaching a temperature of
approx. 135° C.
In this case the safety fuse in the temperature limit controller is activated and pops out. In order to restart the unit the fuse
button has to be pushed down again (see picture Below)
3.3
Initial Start Up
To initially start the Knife Sterilizer proceed as follows:
-
Open the water in
-
feed valve and fill the basin up to the top edge of the stand pipe.
-
Plug
-
in the electrical cable or switch on the mains.
-
The water in the basin is heated to a temperature of 85°C. The time needed to reach this temperature depends on the tem-
perature of the fed
-
in water (at a temp. of 20°C this will take approx. 30 min.).
In compliance with the regulations of hygiene and sanitation, the fresh water supply must remain open to a degree allowing
fat and meat particles as well as other dirt particles to be constantly rinsed off through the stand pipe during operation.
3.4 Operator Safety
The unit must be operated by instructed personnel only.
It is solely purpose
-
designed to sterilize knife blades and is not allowed to be used for any other purposes.
This unit must never be used by children unless attended by an adult.
Fuse button of the temperature limit controller