To adjust water flow, use a small screw driver and turn valve clockwise to shut off or anti –

 

clockwise to open.

 

Forced Water Induction –

 

CAT 67206

 

If you need to force flush, you can flush the toilet mandatory with 
the 

CAT 67206 

valve.  Every time the user pushes the button, the 

valve will flush for 6 seconds and shut off automatically.

 

When the toilet hasn't been flushed for  a long time, the sensor 
will drive the solenoid to flush every 24 hours  to keep it clean 
and deodorised.

 

When user passes into the sensing range for 2 
seconds, the valve will flush for 2 seconds.  
Once the user has left the sensor, the valve will 
flush for 6 seconds. ( LED light will flash once 
every 3 seconds.

 