35
IonWash General Operation
To start using the IonWash all of the previous Electrical and Pneumatic sections of the manual will need to be
completed. Once the IonWash is fully set up and in the correct location it can be switched on.
If there is power to the IonWash and the Isolator is on then the screen should be on. If for any reason the screen
is not on then please check in the trouble shoot guide in the rear of this
manual.
There are three buttons on either side of the IonWash, these buttons are:
Green – Start/Run
Red – Emergency Stop
Blue – Reset
These buttons are the standard control method and how the operators will
use the IonWash.
On both of the operator sides there is a Beacon, this beacon is used to
indicate at what point the IonWash is in the Cycle. The beacon colours
indicate:
Blue: System ready for cycle start
Amber: Standby – One green button has been pressed (2 operator mode)
Green: Cycle start and system running
Red: Fault
The IonWash should be set to remote mode, if the IonWash is not in local mode then it can be done on the touch
screen.
Two Operator mode Operation
The IonWash will be delivered set to 2 operator mode. In this mode both Green buttons on either side of the
IonWash need to be pressed for the cycle to start. The sequence of events are as follows:
1. IonWash on and blue light on beacon is illuminated