14

FAULT - Fuse repeatedly blows

1) Check mains supply
2) Check voltage selector switch for correct setting. 

Maintenance 

 

The only maintenance required is that the exterior of the power supply should be 

cleaned regularly to keep it free from dust and other contaminants. 

Repairs And Warranty

The 905 power supply is warranted by Meech Static Eliminators Ltd to the original 
purchaser against defects in material and workmanship for one year after purchase. 
Should any malfunction occur, please return the power supply directly to Meech 
Static Eliminators or your local distributor. All products returned to the factory MUST 
be accompanied by a return authorisation number and must be shipped prepaid. For 
prompt service, ship the unit to the factory with the return authorisation number shown 
clearly on the label. Be sure it is well packed in a sturdy carton with shock absorbing 
material.

Summary of Contents for 905 Series

Page 1: ...Model 905 Operating Manual High Voltage Power Supply...

Page 2: ......

Page 3: ...her information please refer to our Head Office or visit www meech com Meech Static Eliminators Ltd 26 10 2017 Contents Introduction 3 Input Voltage and Connection 4 Installation 5 Ionising Equipment...

Page 4: ......

Page 5: ...a high voltage output 5 0 kV AC suitable for connection to Meech ionising appliances The Model 905 s unique design features a modified AC output waveform which ensures that ionising appliances attache...

Page 6: ...reasons this equipment must be grounded earthed either via the mains plug or by direct connection to ground earth 4 High voltage output ON indicator Fused mains IEC input socket Ionising appliance con...

Page 7: ...pply Failure of the unit through contamination will invalidate the warranty The Model 905 can operate from either a 110V or 240V switchable AC mains supply It is available in two versions 905 50 for 5...

Page 8: ...lid of the 905 by unscrewing the three retaining screws select the required number of ports one per ionising appliance and remove the necessary grommets from the ports Connect the item of ionising equ...

Page 9: ...n refit both the lock washer and nut to the appliance connector Ensure that the nut is fully tightened Connect the cable eyelet of the appliance to the high voltage stud of the 905 using the screw pro...

Page 10: ...Insert the IEC plug into the IEC socket of the 905 ensuring the illuminated ON OFF rocker switch is in the OFF position Connect the free end of the mains cable to the mains supply For safety reasons...

Page 11: ...9 In normal operation the ON OFF switch will be illuminated red and the High Voltage indicator will be illuminated green...

Page 12: ...ency 50Hz 60Hz Output 5 0kV 5 0kV Short circuit current 5 mA 5 mA Weight 3 4Kg 3 4Kg High voltage indicator YES YES Fuse 500mA 400mA fast Blow fast Blow Dimensions h x w x d 113x150x130mm 113x150x130m...

Page 13: ...ce or your local distributor FAULT High Voltage indicator dim or extinguished 1 Check ON OFF switch is illuminated 2 Check voltage selector switch is set to the correct setting 110v 240 V 3 Check main...

Page 14: ...h on the unit Check to see if the High Voltage indicator is illuminated If illuminated the power supply is OK check ionising appliances attached see appliance Operation and Maintenance Manual Be extre...

Page 15: ...3 mm If no spark is present then the unit is faulty 6 Check ionising appliance integrity see also the appropriate operation and maintenance manual Attach each ionising appliance individually to the 9...

Page 16: ...minators Ltd to the original purchaser against defects in material and workmanship for one year after purchase Should any malfunction occur please return the power supply directly to Meech Static Elim...

Page 17: ...er the warranty Field repairs should not be undertaken during the warranty period Repair attempts by unqualified personnel will invalidate the warranty CE Approval An EC Declaration of Conformity for...

Page 18: ...16...

Page 19: ......

Page 20: ...232 4210 Fax 1 330 564 2005 email info meech com Meech Shavotech 29 2 Kharadi Off Pune Nagar Road On Old Kharadi Mundhwa Road Pune 411014 Maharashtra India Tel 91 0 703 093 8211 91 0 741 000 4817 Fax...

Reviews: