Medline MDS400SA Owner'S Manual Download Page 3

MDS400&600SA (GPI252) 

Revision: 02/16/16

2

sAFETY INsTRucTIONs

The Medline MDS400SA and MDS600SA reflects innovative state-of-the-art design to increase user mobility. The 
MDS400SA and MDS600SA will provide years of service if it is properly maintained, as any piece of electrical/
mechanical equipment requires.
Please pay careful attention to the following important information regarding the care, maintenance, and operation of 
the Medline MDS400SA and MDS600SA Battery Operated Patient Lift. Carefully read the instructions before assembling 
the lifter, or attempting to lift any user with the device.

PLEAsE NOTE ThE FOLLOWINg:

• 

Special care must be taken with residents who cannot provide assistance themselves while being lifted. (i.e. residents 
who are comatose, spastic, agitated, or otherwise severely handicapped.)

• 

The Medline MDS400SA or MDS600SA should be solely for transferring a resident to or from a wheelchair, bed, 
commode, shower chair, floor or 90 degree rotation. The lift should not be used for patient transportations between 
rooms, etc. in lieu of a wheelchair or gurney.

• 

During lifting, whenever possible, always keep the base of the lift in the widest position with the casters locked.

• 

The base of the lift should be closed before moving the lift.

• 

Do not roll casters over any object while the resident is in the sling.

• 

Maximum weight that can be safely lifted is 400 lbs. for the MDS400SA and 600 lbs. for the MDS600SA.

NEVER EXCEED SAFE WORKING LOAD CAPACITY.

The Medline MDS400SA or MDS600SA allows a resident to be lifted and transferred safely with minimum physical 
effort required by the caregiver. Before attempting to lift anyone, please practice operating the lift and read this manual 
completely. Also prior to actual lifting, explain the lifting procedure to the resident.

WARNINg!

Do not attempt to transfer a resident without prior approval of the resident’s nurse or doctor. Also, do not transfer 
without having studied the instructions and practiced operating the lift several times. Together with the resident’s 
doctor, nurse, or medical attendant, select a Medline sling that is both practical and comfortable. The sling selected 
should be one that serves the needs of the resident, while providing the resident with optimal safety. Never interfere 
with the lift, unless instructed by the attendant who should be experienced in the use of the Medline MDS400SA or 
MDS600SA. Never operate the lift unless you have been properly trained on all procedures and safe handling methods.

WARNINg!

Medline slings are specially designed for use on Medline Lift equipment. For optimum performance use only Medline 
stand assist slings. 

USE OF NON-MEDLINE SLINGS IS UNSAFE AND MAY RESULT IN INJURY TO THE RESIDENT OR 

CAREGIVER.

WARNINg!

Do not put anything (e.g. cushion, pad, etc.) between the resident and the sling. This may cause the resident to slide out 
of the sling and cause injury.

Summary of Contents for MDS400SA

Page 1: ...BATTERY OPERATED PATIENT LIFT OWNER S MANUAL MDS400SA MDS600SA Not made with natural rubber latex...

Page 2: ...ping damage Refuse delivery if the package appears to be badly damaged If the merchandise is received damaged or is missing components contact the shipping company immediately and file a claim For fur...

Page 3: ...t that can be safely lifted is 400 lbs for the MDS400SA and 600 lbs for the MDS600SA NEVER EXCEED SAFE WORKING LOAD CAPACITY The Medline MDS400SA or MDS600SA allows a resident to be lifted and transfe...

Page 4: ...of non Medline Lift parts and components WARNING Avoid personal injury by making sure the electrical connector is disconnected before conducting any electrical inspection Contact your dealer if any e...

Page 5: ...for 12 hours 2 Attach boom to top of mast Re insert the bolts into the holes at top of the mast and tighten the nuts 3 1 Attach the bottom actuator to the bracket on the mast and insert pin Insert kee...

Page 6: ...life Battery capacity indicator on battery pack Soft start and stop for lifting actuator Soft and Hardware over current protection Actuator s Over duty protection with sign on LCD Emergency stop butt...

Page 7: ...ED THAT THE BUTTON IS PRESSED DOWN WHEN THE LIFT WILL NOT BE USED FOR OVER 3 DAYS TO MAINTAIN OPTIMAL BATTERY LIFE AND PERFORMANCE PATIENT LIFT WILL NOT OPERATE WHILE CHARGING KG KG Low battery Capaci...

Page 8: ...prevent water ingress REMOVE AND INSERT BATTERY PACK REMOVE Press button A and pull out in the up direction Fig 1 INSERT Insert the battery pack into control box as show in Fig 2 3 While pressing the...

Page 9: ...g points when the Medline MDS400SA or MDS600SA is serviced and every month thereafter Top of mast bolt connection Spreader bar hinge Caster axles CHECKING BATTERY CAPACITY Check batteries by pressing...

Page 10: ...easily on its casters and the casters are firmly attached to base If lift won t roll freely check caster surface for wear and replace if required Lubricate caster axles at each maintenance session El...

Page 11: ...l All controls are easy to use and do not require excessive force DO NOT park a loaded lift on ANY sloping surface DO NOT use electric lifts in a shower DO NOT charge an electric lift in a bathroom or...

Page 12: ...Position sling behind the back with the two red pads under the arms and the single red lumbar pad against the small of the back 3 Make sure the adjustment strap is on the outside 4 Cross the chest be...

Page 13: ...the kneepad Attach the sling straps to the hooks Have the patient s hands holding the handles For patients who cannot hold the handles have them hold their arms around the chest Press the UP button on...

Page 14: ...nually until the patient has been lowered NOTE THE EMERGENCY LOWERING DEVICE IS INTENDED FOR USE DURING LIFT FAILURE THIS DEVICE WILL ALLOW LOWERING OF PATIENTS ONLY LIFT SPECIFICATION CHART ITEM NUMB...

Page 15: ...charge Control Box Charger still plugged in Poor connection between control box and hand control or defective hand control Poor connection between actuator and control box Unplug charger Plug hand con...

Page 16: ...odel Name Number and Serial Number on the packaging 2 Proof of purchase i e copy of the original invoice from either Medline or its dealer 3 A Return Authorization number RA obtained by calling Medlin...

Page 17: ...medline com Medline United States 1 800 MEDLINE 633 5463 www medline com info medline com Medline Industries Inc One Medline Place Mundelein IL 60060 Some products may not be available for sale in Mex...

Reviews: