Meditub 3060WCA Installation & Operating Instructions Manual Download Page 5

Page 7

OPERATING INSTRUCTIONS

OPER

ATIN

G

  INSTRUCTION

S

Page 6

W H E R E   S A F E T Y   M E E T S   L U X U R Y

W H E R E   S A F E T Y   M E E T S   L U X U R Y

SA

FE

TY

SAFETY

PRE-INSTALLATION*

* All Walk-In Bath Tubs are 100% water tested at the factory certified to be free of leaks. Transportation and mishandling may cause leaks. It is necessary to test the bathtub while there is access to 
all sides of the bathtub.

READ AND FOLLOW ALL INSTRUCTIONS

   Place the tub on a completely flat surface in an area where it may be drained after testing.

  Close the drain and fill the tub until it is above the highest jet. If it’s a soaker fill up to normal water height level.

  Allow the water to stand in tub for 30 minutes and then inspect all plumbing and seals for leaks. 

  If tub is jetted, supply electric to unit and run for 10 minutes and inspect for leaks. Inspect the unions around the pump; if 

leaks 

persist from the unions after tightening; loosen the unions and insure the O-ring is seated properly. 

NOTE: IF THE PUMPS DO NOT OPERATE, CHECK THE BREAKER TO ENSURE POWER IS ON AND THE CABLE CONNECTING THE 

CONTROLS TO THE PUMP IS ATTACHED.

WARNING!

  DO  NOT  RUN  ANY  PUMPS  UNLESS  THE  TUB IS FILLED WITH WATER  TO  PROPER  

LEVEL. DAMAGE DUE TO DRY RUNNING PUMPS IS NOT COVERED UNDER WARRANTY. FAILURE TO 

PERFORM THESE TESTS BE FORE INSTALLATION WILL MAKE THE INSTALLER LIABLE FOR FUTURE 

REPAIR COSTS.

INSTALLATION PREPARATION

1.  Check the floor area where the tub is to be installed.

  a. Clean area of any debris or trash.

  b. Use a 5 or 6-foot level and determine if the floor is level. If the floor is not level, adjust all 5 leveling feet to perfectly level the tub.

 

NOTE: IT IS  IMPORTANT THAT ALL LEVELING FEET ARE COMPLETELY TOUCHING THE FLOOR 
AND LEVEL FOR THE DOOR SYSTEM TO WORK PROPERLY.

2.  Check to ensure that the drain piping has been “roughed-in” at the proper location.

3.  Ensure that the proper electrical service has been installed at the pump location. See electrical requirements in the manual (on 

following page).

Model 30x53

Installation Instructions

 

 

 

   

 

 

MediTub

W h e r e   S a f e t y   M e e t s   L u x u r y

Summary of Contents for 3060WCA

Page 1: ...W H E R E S A F E T Y M E E T S L U X U R Y INSTALLATION OPERATING INSTRUCTIONS INSTALLATION OPERATINGINSTRUCTIONS 3060WCA MODEL www agingsafelybaths com ...

Page 2: ...PRE INSTALLATION 6 INSTALLATIONPREPARATION 7 ELECTRICALPREPARATION 8 INSTALLATIONPROCEDURES 9 DRAINCONNECT ION 10 CONNECT INGTHE AUTODRA IN 11 INSTALLATIONANDEXTENS IONPANELS 12 FAUCETINSTALLATION 13 OPERATINGSAFETY INSTRUCTIONS 14 OPERATINGINSTRUCTIONS 16 TUBCONTROLS 18 CLEANINGANDMAINTENANCE 19 WARRANTY 20 RETURN POLICY 22 PRODUCTREGISTRATIONCARD 23 TABLE OF CONTENTS TABLE OF CONTENTS ...

Page 3: ...1060 info meditub com http www meditub com THANK YOU CONTACT PRODUCT REGISTRATION PRODUCT REGISTRATION PRODUCTREGISTRATION ToensurethatyourwarrantyisregisteredwithMeditubWalk InBathtubs complete signandreturnthisregistrationcardwithin30daysofthepurchase NOTE Yourwarrantywillnotberecognized byMeditubWalk InBathtubs unlessthiscardisfullycompletedandreturnedto MeditubWalk InBathtubs 5701NW35thAve Mia...

Page 4: ...TY FOR THE CORRECT INSTALLATION PROCEDURES ONLY ACCESSORIES AUTHORIZED BY THE MANUFACTURERSHOULDBEUSEDWITHTHISPRODUCT IMPORTANTSAFETYINSTRUCTIONS WARNING WHENUSINGTHIS PRODUCT BASICPRECAUTIONSSHOULDALWAYS BEFOLLOWED READANDFOLLOWALLINSTRUCTIONSPERTAININGTORISKOFFIRE ELECTRICALSHOCK AND OROTHER INJURIES SAVE THIS MANUAL UNPACKING UNPACKING UNPACKINGTHE UNIT INSPECTINGTHE PACKAGING Inspectthecarton ...

Page 5: ...theunionsandinsuretheO ringisseatedproperly NOTE IFTHEPUMPSDONOTOPERATE CHECKTHEBREAKERTOENSUREPOWER ISONANDTHECABLECONNECT INGTHE CONTROLSTOTHEPUMP ISATTACHED WARNING DO NOT RUN ANY PUMPS UNLESS THE TUB IS FILLED WITH WATER TO PROPER LEVEL DAMAGEDUETODRYRUNNINGPUMPS IS NOTCOVEREDUNDERWARRANTY FAILURETO PERFORMTHESETESTSBE FORE INSTALLATIONWILL MAKETHE INSTALLERLIABLEFORFUTURE REPAIRCOSTS INSTALLA...

Page 6: ...ssage Or Air Massage w Light 15 Amp GFCI Jet Massage Or Air Massage w Auto Drain 15 Amp GFCI Jet Massage Or Air Massage w Light Auto Drain 15 Amp GFCI Jet Massage Air Massage Dual 20 Amp GFCI Jet Massage Air Massage Dual w Light 20 Amp GFCI Jet Massage Air Massage Dual w Auto Drain 20 Amp GFCI Jet Massage Air Massage Dual w Light Auto Drain 20 Amp GFCI Whirlpool Inline Heater Dedicated 15 Amp Circ...

Page 7: ...ies Once thehoseisinplace closethedoorontheunit placethehandleinthelockedposi tion andfilltubwithatleast12 ofwatertotesttheconnection Oncethecompletion of the drain components are installed and have been tested for proper function the unit can be leveled and give a final water test beforeinstallationofunit Figure2 1 1 2 Door Drain Pipe supplied 7 1 2 FIGURE1 Floor Drain Incorrect Flow Door Drain C...

Page 8: ...S L U X U R Y FAUCETINSTALLATION fixing nut fixing nut fixing nut hot control handle cold control handle spout shower head diverter rubber washer fiber washer valve body gasket steel braded 19 hose steel braded 19 hose 72 shower hose local water line hot water cold water SIDE ACCESS PANELS FOR 3 SIDE ENCLOSURE ASSEMBLY PLACEMENT Verifyaccesstounit ssystemfromoneofthesideenclosures ...

Page 9: ...our feetofthisbathtub Neverdroporinsertanyobjectsintoanyopenings Donotoperatethisunitwithouttheguardoverthesuctionfittings WARNING RISKOF HYPERTHERMIAANDPOSSIBLEDROWNING Peopleusingmedications herbalremedies sleepaids and orhavingadversemedicalhistoryshouldconsultaphysicianbeforeusingthisproduct WARNING NOFOODORALCO HOLICBEVERAGES Useofyourbathtubimmediatelyaftermealsisnotrecommended Avoid alcohol...

Page 10: ...zlefordirection Turneithertheoutsideringorthenozzleclockwise orcounterclockwiseforflow somejetsadjusttheflowwiththeoutsideringandsomewiththenozzle Adjusttheairpressureflow ofallwaterjetsbyusingthe airvolumecontrol seepage18 whichcontrolsair watermixture Meditubwalk intubsequippedwiththechromotherapylights orderedseparately featureadedicatedon offswitch Pressingthe switchoffandbackonwillchangetheco...

Page 11: ...placeasneeded 1 2 3 4 6 5 Controlsdepictedmayvaryfromthosefoundonyourunit Varianceisbasedonthe optionspurchasedduringtheorderprocess CLEANINGANDMAINTENANCE Pumpandpipecirculationsystemsshouldbeflushedbeforefirstuseandonamonthlybasiswhenproductisundernormaluse Belowaretherecommendedproceduresforcleaning Do notrunwhirlpooldry Fill thetubwithhotwater2 3 inchesabovethejets andadd2 3 teaspoonsof lowfoa...

Page 12: ...a charge for replacement parts or the replacement of the entire electrical unit if the defective unit is returned for any of the reasons listed above NOTE WITHIN THE LIMITED ONEYEAR WARRANTY THERE WILL BE A PRORATED CHARGE FOR ANY ELECTRICAL AND PLATEDREPLACEMENTSPARTS INCLUDINGSHIPPINGANDHANDLINGCHARGES Manufacturer reserves the sole authority to make any type of warranty changes at any time The ...

Page 13: ...Allreturnswillreceivea 15 restockingfeeplusall freightcostsoftheoriginalshipmentandreturnshipmenttoMeditubWalk InBathtubs AllrequestsforreturnmustfirstbeapprovedbyMeditubWalk InBathtubs andhaveanassigned ReturnedMerchandise Authorizationnumber RMA RETURN POLICY RETURN POLICY Meditub Walk InBathtubs Product Registration Card Name Address City State Zip Phone Date of Purchase Dealer Address Installe...

Page 14: ...W H E R E S A F E T Y M E E T S L U X U R Y INSTALLATION OPERATINGINSTRUCTIONS INSTALLATION OPERATING INSTRUCTIONS W H E R E S A F E T Y M E E T S L U X U R Y ...