Blood Pressure Q & A

Q:  What is the difference between measuring blood pressure at home versus    
 

measuring blood pressure at the clinic or doctor?

A:  Readings taken in a clinical environment may be higher than usual due to  
 

the patient feeling anxious. This is known as White Coat Hypertension.  

 

Therefore readings taken at home at the same time each day are seen to  

 

give a more accurate account. 

 

  Note: Abnormal test results may be caused by:

 

  1.    Improper cuff placement - ensure the cuff is snugly fitted and is 
         not too tight nor too loose. The bottom of the cuff should be 

 

         approximately 1-2cm (½”) above the elbow joint.

 

  2.    Improper body position - ensure your body is kept in an upright  

 

         position with your arm relaxed.

 

  3.    Feeling anxious or nervous - take 2 or 3 deep breaths and relax. 

 

         Wait a few minutes and retest.

 

  4.    Moving or talking during measurement - do not move or talk 

 

         during measurement. Breathe normally and relax.

Q:  What causes different readings?
A:  Blood pressure varies throughout the course of the day. Many factors may  
 

affect a person’s blood pressure including diet, stress, cuff placement, levels 

       of hydration.

Q:  Which arm should I apply the cuff to? What is the difference?
A:  Testing on the left arm may provide more accurate results as it is closest to  
 

the heart however either arm can be used. Ensure that when results are   

 

compared that the same arm has been used. Do not mix left and right arm  

 

results.

Q:  What is the best time of day for testing?
A:  Generally when you wake up in the morning before you get out of bed but  
 

otherwise any time of the day when you feel relaxed and stress free.

Maintenance

1.  Avoid dropping, slamming or throwing the unit.

2.  Avoid extreme temperatures. Do not expose the unit directly to sunshine.

3.   Use a soft cloth and mild detergent to gently wipe the unit clean.
      Use a damp cloth to wipe away excess detergent or dirt. 
 

Do not let liquid get into the unit. 

Specifications*

Maintenance

4.  Cleaning the cuff: Do not soak the cuff in water! Apply a small amount of  

 

 

rubbing alcohol to a soft cloth to clean the cuff’s surface. Use a damp cloth    

 

(water-based) to wipe clean afterwards. Allow the cuff to dry naturally at     

 

5.  Do not use petrol, thinners or similar solvents.

6.  Remove batteries when not in operation for an extended period of time.

7.  Do not disassemble the unit.

8.  Expected service life: approximately 3 years at 30 tests per day.

Product Description

Arm-Type Fully Automatic Digital Blood Pressure Monitor

MGX-1209

Model

Display

LCD Digital Display Size: 62.7 x 46.4mm (2.47” x 1.83”)

Measurement Range

Measurement Method Oscillometric Method

Measurement 
Accuracy

Pressure

Pulse

0mmHg - 300mmHg

30 - 180 beats per minute

Pressure

Pulse

±3mmHg

±5%

Pressurization

Memory

Functions

Power Source

Battery Life

Unit Weight

Unit Dimensions

Cuff Circumference

Operating 
Environment

Storage
Environment

Classification 

Humidity

Temperature

Temperature

Humidity

5

˚

C - 40

˚

C   (41

˚F

 

- 104˚F)

-10

˚

C - 55

˚

C   (14

˚F - 131˚F)

85%RH

<95%RH

Internal Powered Equipment, Type B     , Cuff is the Applied Part

*Specifications are subject to change without notice

Automatic Pressurization

2 x 60 Memories

4 AA batteries provided

Approximately 2 months at 3 tests per day

Approximately 240g (excluding batteries)

Approximately 134 x 99 x 66mm (5.28” x 3.90“ x 2.60”) (LxWxH)

Approximately 135 x 485mm (WxL)
Fits arm circumference 22 - 42cm (8.6 - 16.5 inch)

room temperature.

Irregular Heartbeat Detection
WHO Classification Indicator
Last 3 Results Average
Low Battery Detection
Automatic Power Off

SY

S

PU

L

DIA

m

m

min

/

m

m

H

H

g

g

ME

M

ST

OP

ST

AR

T

SYS

PUL

DIA

m

m

min

/

m

m

H

H

g

g

ME M

S T O P

S TA R T

SYS

PUL

DIA

m

m

min

/

m

m

H

H

g

g

ME M

S T O P

S TA R T

Summary of Contents for MGX-1209

Page 1: ...er better Please consult your doctor for specific information about your blood pressure European Authorized Representative Shanghai International Holding Corp GmbH Hamburg Eiffestrasse 80 20537 Hambur...

Page 2: ...iGenix Upper Arm Automatic Digital Blood Pressure Monitor MGX 1209 Battery Precautions Do not mix old and new batteries simultaneously Replace batteries when Low Battery Indicator Arm Cuff Display The...

Page 3: ...with severe arrhythmia Battery Installation 1 Install batteries see Figure A 2 Insert the cuff air plug into the left side of the monitor unit see Figure B Figure A Figure B Figure C 3 Remove clothin...

Page 4: ...appear simultaneously on screen signaling heart beat detection Note Relax and do not move or speak during testing 4 Result Display Three short beeps sound when the testing is complete The screen will...

Page 5: ...uently changes throughout the course of a day Excitement or stress can cause blood pressure to rise whilst drinking alcohol or bathing can lower blood pressure Certain hormones like adrenaline which o...

Page 6: ...not expose the unit directly to sunshine 3 Use a soft cloth and mild detergent to gently wipe the unit clean Use a damp cloth to wipe away excess detergent or dirt Do not let liquid get into the unit...

Page 7: ...010 clinically validated for BP 1209 Correct disposal of this product Waste electrical Electronic Equipment This marking shown on the product indicates that it should not be disposed of with other hou...

Reviews: