background image

3

FILTER PURIFICATION

1.

  PRE FILTER 

 

Removes hair, fibers, and large particles like dander. 

2.

  TRUE HEPA H13 FILTER

 

The high-efficiency H13 TRUE HEPA filter is tested to removed 99.9% of particles down to 0.1 microns. 
This higher grade of HEPA filter easily catches pollen, dust mites, and other tiny airborne particles you 
can’t see. 

3.

  ACTIVATED CARBON FILTER

 

Substantial carbon filter with carbon pellets remove toxic odors, smoke, and formaldehyde.

¹

²

To purchase genuine Medify replacement filters, visit www.medifyair.com.

PREFILTER
catches large particles 
like hair and dust

TRUE HEPA H13 FILTER
catches 99% of particles to 0.1 
microns including pet dander 
and pollen

³

ACTIVATED CARBON FILTER
absorbs and eliminates odors

Summary of Contents for MA-40

Page 1: ...MA 40 AIRPURIFIER READ AND SAVE THESE INSTRUCTIONS INSTRUCTION MANUAL AND WARRANTY INFORMATION Lifetime warranty if replacing filters on time MA 40 US Rev 09 04 21 ...

Page 2: ... ruin the circuit boards if you plug a 110v plug into a 220v power supply BEFORE USING THIS PRODUCT PLEASE MAKE SURE TO REMOVE THE PLASTIC COVERING FROM ALL FILTERS Turn off the power immediately in case of any of the following Malfunction of any switch Circuit failure Abnormal heating of wires or plugs Any other malfunction If the supply cord is damaged it must be replaced by the manufacturer its...

Page 3: ...tches pollen dust mites and other tiny airborne particles you can t see 3 ACTIVATED CARBON FILTER Substantial carbon filter with carbon pellets remove toxic odors smoke and formaldehyde To purchase genuine Medify replacement filters visit www medifyair com PREFILTER catches large particles like hair and dust TRUE HEPA H13 FILTER catches 99 of particles to 0 1 microns including pet dander and polle...

Page 4: ...PA H13 FILTER AND ACTIVATED CARBON FILTER BACK COVER AIR INLET HANDLE CLEAN AIR OUTLET CONTROL PANEL FRONT PANEL PRE FILTER TRUE HEPA H13 FILTER AND ACTIVATED CARBON FILTER BACK COVER TECHNICAL DATA Voltage 110 120 V AC 60 Hz North America Japan Rated power 68 W Noise level 66 dB A Unit dimensions 22 H x 9 9 W x 10 9 D Unit weight 15 5 lbs ...

Page 5: ...er and pull out slightly 2 To reinstall the side covers align the fixed slots and insert the covers into the slots The covers will automatically snap back into place Do not obstruct the air intake or the clean air outlet To ensure proper air circulation leave at least 1O space between the back air intake and the wall or the furniture 10 inch 10 inch 10 inch ...

Page 6: ...nstalling the new filter make sure to push it back in and make sure that it is affixed snuggly for maximum performance 1 Place the machine in a dry location and on a smooth and flat surface 2 Press the top buttons in the back cover and pull the cover Lift the back cover and pull out slightly 3 Remove the filter by pulling on the small tab at the top of filter ...

Page 7: ...Place the new filter in the air purifier with the white side facing out towards you The tab at the top of the filter should be facing you 6 Replace the back cover Remove all plastic packaging from the filter before installing it DO NOT run the air purifier if there is no filter installed ATTENTION ...

Page 8: ...e power button The unit will start working in low speed Press the button again so the machine stops and enters standby mode This air purifier has 4 fan speed settings low medium high and sleep mode The higher the fan speed setting the faster the air will be purified To select or change fan speed press the fan speed button until the desired setting is reached TIMER Press the timer button and choose...

Page 9: ...hen Ionizer is on the indicator light will be lit CHILD LOCK BUTTON In this mode none of the function keys can be used or changed except the child lock function To turn on the child lock hold the button down for 3 to 5 seconds To turn off the child lock function hold the button down for 30 to 45 seconds ...

Page 10: ...so make sure that both the air intake and the vents are free from dust DO NOT vacuum or try to wash the filter as it will clog it FILTER REPLACEMENT LIGHT INDICATOR TO REPLACE THE FILTER It reminds the user when the filter needs to be replaced The indicator icon will become lit when the filter needs to be replaced 1 lndicator Lights will show the user if the filters need to be replaced Make sure t...

Page 11: ...the new filter in the air purifier with the white side facing towards you 5 Replace the back cover 6 Resetting the Filter indicator Light Once the new filter has been installed and the unit is turned back on Hold down the FAN SPEED button and the IONIZER button at the same time for 3 5 seconds Then the indicator light will go off and the timer will be reset for 3000 hours ...

Page 12: ...nit at no charge to you and reimburse you for any shipping charges After 30 days Medify Air s obligation and liability under this Lifetime Warranty is dependent on your use of our genuine filters purchased on our website or from our authorized resellers which can be found on our website Prohibited use beyond power Can only use a 220v unit with a 220v power supply Can only use a 110v unit with a 11...

Reviews: