IMPORTANT SAFETY INSTRUCTIONS:

IN ORDER TO AVOID ANY DAMAGE TO YOU, OTHERS OR PROPERTY, FOLLOW THE FOLLOWING SAFETY PRECAUTIONS:

IF THE POWER CORD OR UNIT DOES NOT WORK, CONTACT MEDIFY CUSTOMER SERVICE IMMEDIATELY.

READ ALL INSTRUCTIONS BEFORE USING.

WARNING –

 

TO REDUCE THE RISK OF BURNS, FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS

:

•  DO NOT touch the power plug with wet hands.
•  Turn off the power before cleaning the unit.
•  DO NOT use the air purifier in rooms where fumigation or pesticide is being used.
•  Keep the unit dry.
•  DO NOT use air purifier in a room where it is being cooked with oils and grease that may clog the filters.
•  Use ONLY a soft clean cloth. DO NOT use solvents like Benzene, Alcohol or any flammable cleaners to 

clean the air purifier.

•  This is a 220-240V unit. It is NOT made for 11OV use. Plugging it into a 11OV outlet will damage the 

motor and circuits and the unit will no work any longer. Use only with a 220-240V outlet.

•  Turn off the power immediately in case of any of the following:

-Malfunction of any switch
-Circuit failure
-Abnormal heating of wires or plugs
-Any other malfunction

CORRECT DISPOSAL OF THIS PRODUCT

If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in 
order to avoid any type of hazard. This appliance can be used by children aged from 8 years and above and people with 
reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision 
or instruction concerning the use of the appliance in a safe way and understand the hazards involved. Children shall not 
play with the appliance. Cleaning and maintenance of the unit shall not be made by children without supervision. Prior to 
cleaning or doing any type of maintenance, the appliance must be disconnected from the supply.

SAVE THESE IMPORTANT INSTRUCTIONS FOR EASY REFERENCE.

This symbol indicates that this product should not be disposed with other household wastes 
throughout the EU. To prevent possible harm to the environment or human health from 
uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of 
material resources. To return your used device, please use the return and collection systems 
or contact the retailer where the product was purchased. They can take this product for 
environmental safe recycling.

Summary of Contents for MA-112

Page 1: ...MA 112 AIRPURIFIER MA 112 READ AND SAVE THESE INSTRUCTIONS INSTRUCTION MANUAL AND WARRANTY INFORMATION Lifetime warranty if replacing filters on time ...

Page 2: ...y other malfunction CORRECT DISPOSAL OF THIS PRODUCT If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid any type of hazard This appliance can be used by children aged from 8 years and above and people with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given ...

Page 3: ...articles down to 0 1 microns as well as PM2 5 particles such as smoke pollen dust mites and others 3 THIRD STEP ACTIVATED CARBON FILTER Absorbs odors harmful VOCs and other toxic substances such as formaldehyde 4 FOURTH STEP IONIZER GENERATOR Produces negative ions to neutralize positively charged particles such as dust bacteria mold spores pollen animal dander and other airborne positive particle...

Page 4: ...1 H x 15 711W x 15 411 D Unit weight 32 8 lbs CONTROL PANEL INDICATOR LIGHT OF AIR QUALITY FRONT PANEL LEFT COVER RIGHT COVER PRE FILTER PRE FILTER TRUE HEPA H13 FILTER ACTIVATD CARBON FILTER NET TRUE HEPA H13 FILTER ACTIVATD CARBON FILTER NET HANDLE AIR OUTLET COVER SENSOR COVER BACK COVER AIR INLET ...

Page 5: ...s down on the handles on the sides to remove the side covers After they open lift the cover out from the bottom fixed grooves 2 To reinstall the side covers align the fixed slots and insert the covers into the slots The covers will automatically snap back into place 50cm 50cm 50cm Air Quality Indicator Light Index INDICATOR LIGHT OF AIR QUALITY Blue Excellent Green Average Red Poor ...

Page 6: ...r nearby furniture 1 Place the machine in a dry location and on a smooth and flat surface 2 Press down on the handles on the sides to remove the side covers Once they are open lift the cover out from the bottom fixed grooves INSTALLING THE FILTER SET All filters must be used together Please remove the filters according to the following instructions Reinstall the filters accordingly 50cm 50cm 50cm ...

Page 7: ...fficiency 4 Remove any exterior packaging of the filter sets Place the filters back in the air purifiers once the packaging has been removed 5 To reinstall the side covers align the fixed slots and insert the covers into the slots The covers will automatically snap back into place ...

Page 8: ...all other indicator lights will turn off The fan speed and noise level will change to the lowest setting After 10 seconds the sleep indicator light goes out as well Press any key to exit sleep mode TIMER Press the timer button and choose your preferred hour options 1 2 4 8 or no timer CONTROL PANEL FILTER REPLACEMENT INDICATOR CHILD LOCK INDICATOR 1H 2H 4H 8H TIMER INDICATOR SLEEP INDICATOR CHILD ...

Page 9: ... to 5 seconds To turn off the child lock function hold the button down for 30 to 45 seconds CLEANING AND MAINTENANCE Please make sure to pull out the power plug before cleaning the unit Do not put the unit in water or in any other liquid Do not use abrasive corrosive or flammable products to clean any parts of the unit The unit uses composite filters so filters cannot be washed CLEANING THE AIR PU...

Page 10: ...ut the sensor area or use a vacuum cleaner Either works well to clean the sensor 4 Reinstall the cover of air quality sensor The air quality sensor may accumulate condensation If this happens the air quality sensor even if in a ventilated room may show poor air quality Please make sure the air quality sensor is clean and dry to perform properly ATTENTION ...

Page 11: ...as existing filters Turn off and pull out power plug before replacing the filters If replacement filter indicator light flashes again after replacement press the reset button at the side as shown until indicator light resets itself ATTENTION 2 Install new filter sets in the unit Reinstall side covers as outlined earlier Side covers will snap back in automatically 3 When filter replacement is compl...

Page 12: ...00 hours of use The filter replacement indicator will let you know when it is time to replace it Medify Air will replace the defective unit at no charge to you and reimburse you for any shipping charges After 30 days Medify Air s obligation and liability under this Lifetime Warranty is dependent on your use of our genuine filters purchased on our website or from our authorized resellers which can ...