METHOD OF USE
Correct cleaning of the machine will lenghten its working life considerably.
When in use, the machine will accumulate dust inside which should be cleaned out if used regularly,
at least ONCE A YEAR.
PREVENTATIVE MAINTENANCE AND CLEANING
1. Disconnect the dryer lead-in wire.
2. Unscrew the 4 side attachment screws using a Phillips
screwdriver.
3. Remove cover (See dismantling for installation).
4. Remove the accumulated dust in the fan wheel with a
soft bristle brush.
5. Using the same brush, remove the dust accumulated in
the out grill.
6. Brush the sides between the support and the wall.
7. We recommend removing the machine from the wall and
unscrewing the four mounting bolts to remove any
obstructions (paper, cigarette ends, etc.)
Machine must be handled only by an autorized technician.
WARNING: When dismantle the cover, electrical live and basic insulated parts are accesible.
To dry hands correctly, we recommend rinsing well to remove all traces of soap. Once the dryer is working, hold
the hands at an approximate distance of 2.5”÷3” (6÷7 cm) and rub together. The hands can be gradually taken
away from the dryer and will continue drying up to a maximum distance of 4"÷6" (10÷15 cm).
Automatic models:
These models operate by hand detection. If hands are held 4"÷6" (10÷15 cm) from the air discharge nozzle,
the dryer will start working and will stop 2÷3 seconds after use.
If the sensor is blocked due to vandalism, the dryer will completely stop working.
Please, concerning automatic models, let a minimum separation of , 16” (40 cm) between appliance and any
shelf, marble, worktop or washbasins.
Pushbutton
Sensor
CLEANING METHOD
3
M88-UL
M88A-UL
M89A-UL
110-120V 50/60 Hz
11A
1.7Hp (1300 W)
6.616 lb (3 kg)
8.316 lb (3,75 Kg)
1/7Hp (100 W)
Shaded pole Motor
Single inlet centrifugal fan
1.6Hp (1200 W)
Timer
IR Sensor
45 s _
11.8” (300 mm)
9.8” (250mm)
5.1” (130mm)
ABS
Aluminium
UL 499
140 CFM(4000 l/min)
3,900 LFM(71 Km/h)
124 º F(51ºC)
MODEL
Input voltage
Consumption
Rated power
Weigth
MOTOR:
Power
Type
SCROLL-FAN
HEATING ELEMENT:
Power
TIMER:
Type
Drying cycle
DIMENSIONS:
Height
Widht
Depth
COVER:
Type
Certified in accordance with:
Air flow
Air velocity
Air temperature
Caution: do not damage or force any machine part.
8. When maintenance is complete, screw the base to the
wall (if applicable), re-mount the cover, tighten up the
screws and plug in.
9. In case of having dismantled the air outlet, install it again
in its place and ensure that it is in its proper position
10. Switch on the machine and leave running until all traces
of dust from the cleaning proces have been discharged