(2)
OPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS
11
10
2
1
3
4
5
6
7
Operating
Instructions
CAUTION
If the water in the tank is decreasing, the red warning light “Water Shortage” (06E) switches on and the warning
light (11F) on the hand grip blinks, followed by an intermittent signal tone. The power supply to the heating
element is cut off until the water tank (01) is filled again.
Fill water in the tank and confirm by pressing the button (06B).
This device is equipped with a double control system that checks if there is water and thus monitors the liquid in
the refill tank as well as in the boiler as follows:
The system checks both the tanks each time the device is switched on, first the boiler and then the refill tank. If
the liquid level in the boiler is insufficient, the system automatically restores the liquid level in it, in which case the
warning light Water Shortage switches on for the duration of this action (approx. 3 seconds).
If the warning light Water Shortage continues to remain on and is accompanied by an acoustic signal tone, then
it is indicative of a liquid shortage in the tank; the tank must be filled.
1
Before using your Medicleantec, ensure that
the surface of the appliance does not have any
damage. Check if the volt and ampere ratings of
your power source match the data on the appliance
sticker.
2
Remove the tank cover (1) from the appliance
and fill the reservoir with at least 1 liter of water.
You may use straight tap water, distilled or os-
mosis water. Please do not fill any chemicals in
your Medicleantec.
3
Connect the power cord (03) to an outlet.
4
Connect the steam plug (12) to the designated
appliance accessory outlet (05). Press firmly until
the securing button (13) is engaged.
5
Press the main switch (2) at the back of the
appliance, switch (06A) and the steam boiler
button (06B) and wait for approx. 5 minutes until
the indicator light (06D) is illuminated. It indicates that
the boiler has steam. The switches (11A and 11E) on
the handle should be off.
6
When the indicator light (06D) is illuminated, you
can adjust the desired steam flow (steam button
11A) as follows:
a. pressed 1x = Minimum steam (11B)
b. pressed 2x = Medium steam (11C)
c. pressed 3x = Maximum steam (11D)
Press the steam button (10) to release steam. The
status is displayed on the control panel (indicator
lights (06C)).
7
Using the button (11E) allows you to add hot
water to the steam.
Press the button only at short intervals (a few se-
conds) to avoid discharging the generator too quickly.
The switch (11E) only functions if the boiler switch
(06B) was also pressed.