background image

   

MC-306

 

 
 

 

 

 

 

 

In order to use this product safely, please read the manual before use.   

 

After reading, please keep it in a safe place for easy check and reference. 

Summary of Contents for Infrared MC-306

Page 1: ...MC 306 In order to use this product safely please read the manual before use After reading please keep it in a safe place for easy check and reference ...

Page 2: ...arance diagram 4 8 Structure and composition 4 9 Display icons and definitions 4 10 Setting operation 5 11 Measuring method 7 12 Installation and replacement for battery 7 13 Maintenance 8 14 Special storage and transportation condition 8 15 Troubleshooting 9 16 Technical Specification 10 18 Explanation of graphic and symbol 11 19 Quality commitment and after sales service 12 ...

Page 3: ...ture of the thermometer changes greatly such as from indoor to outdoor please wait for about 30 minutes in the new environment before measuring It is recommended that the interval be more than 10 seconds for multiple measurements The user is not familiar with the measuring method which may cause measuring deviation It is recommended that users purchase this product and practice several times to be...

Page 4: ...n the forehead Trial population suitable for infants children and adults Expected use environment The environment applicable to this product includes hospitals clinics infirmaries schools government organizations social groups and families 5 Working principle Any object will release infrared radiation energy and its surface temperature directly determines the size and wavelength of the radiant ene...

Page 5: ... Software release version No V1 memory power supply electro acoustic components LED display and housing Product accessories instruction manual warranty card certificate of conformity 9 Display icons and definitions Definition of icon Icon Description of Status Display value 1 Display value during the measurement Temperature unit 2 Celsius ...

Page 6: ... completing the self check enter the standby mode and the screen display is as shown in Figure 2 Fig 1 Fig 2 Align the probe area with the forehead of the person to be measured within a suitable distance and press the Measurement Switch the thermometer will vibrate for a short time the screen display is shown in Figure 3 and report the measurement result If the distance from the probe area to the ...

Page 7: ...n and keep pressing down for more than 8 seconds and press the side button Room Temperature the thermometer enters the factory setting mode the screen display is shown in Figure 11 Fig 11 Body temperature mode setting press the upper part of side button to enter the 3 mode section press the lower part of side button to adjust to the 1 section the screen displays as shown in Figure 12 press the mai...

Page 8: ...put the thermometer in the new environment for about 30 minutes before measuring 11 3 When the measurement object comes from a place with a large difference in temperature from the measurement environment the measurement object should stay in the test environment for at least 5 minutes 11 4 Try not to measure with forehead blowing water dripping sweating applying cosmetics etc Do not measure tempe...

Page 9: ...clean soft cloth or cotton stick with a little medical alcohol Use it after the alcohol has completely evaporated 12 3 No special maintenance is required during use please contact the seller or manufacturer if there is a failure Please dispose of the waste and residue at the end of the service life of the product according to the local laws and regulations 14 Special storage and transportation con...

Page 10: ...ct the measurement difference will occur Leave it for about 10 minutes to obtain a new test heat balance before using it 3 The best operating environment of the product is 16 ºC 35ºC check whether the current environmental temperature is too low or too high 4 Check the distance of measurement 3 5cm Screen displays LO or HI 1 The temperature of the tested object is lower than 34 1ºC the screen disp...

Page 11: ...omatic shutdown within 25 seconds Size 146 X 35 X 41 mm Weight 68g Classification by type of protection against electric shock Internal power supply equipment Classification by degree of protection against electric shock B type application part Classification according to the degree of protection for liquid inlet No liquid inlet protection Classification by operating mode Continuous operation Whet...

Page 12: ...at the content of this toxic and hazardous substance in all homogeneous materials of this part is below the limit requirement specified in SJ T11363 2006 indicates that the content of this toxic and hazardous substance in at least one homogeneous material of the part exceeds the limit requirement specified in SJ T11363 2006 18 Explanation of graphic and symbol Pay attention to the warning refer to...

Page 13: ... sales service This product has a service life of 5 years and provides one year of free repair service Note Any failure caused by the user s personal reasons or any damage caused by unauthorized dis assembly will not provide a free repair period Tip Please keep your purchase voucher for future maintenance ...

Reviews: