![Medical Solutions 16N1 Operator'S Manual Download Page 12](http://html1.mh-extra.com/html/medical-solutions/16n1/16n1_operators-manual_1760974012.webp)
5695.B
9
11.
The display will flash “P2 Cloc”.
12.
Press and release the blue RESET button.
5.2
Code Lock Instructions
To Unlock the Code Lock, enter the Sub-Master Code (Preset to 8-7-6-5-4-3-2-1) or User
Code (Preset to 2-2-4-4) and turn the Code Lock handle clockwise to the open position (see
Figure 2).
o
NOTE: Entering three incorrect codes will cause the lock to shutdown for 10 seconds.
The red indicator light on the Code Lock will illuminate if an incorrect code is entered.
A correct code is indicated by the illumination of the blue light on the Code Lock.
The Code Lock is powered by two (2) AAA 1.5v batteries and should provide well in excess
of 15,000 openings of 4 seconds each. If the batteries are low in power, the Red LED will
flash 3 times before the Blue LED flashes to signal acceptance of the code. If this occurs or
the batteries fail, contact Medical Solutions, Inc. at 800-435-7600.
5.2.1
Changing the Code Lock Sub-Master Code
o
NOTE: To program the Code Lock, the lock must be in the open position with the #
button visible and the door to the 16
N
1
®
should be open.
1.
Press the red “#” button located under the Code Lock handle (see Figure 2).
2.
Enter the current Sub-Master Code.
3.
Enter 0-6 and verify a 1 second blue LED flash.
4.
Enter a new eight (8) digit Sub-Master Code and verify a 1 second blue LED flash.
5.
Enter the new Sub-Master Code again and verify two 1 second blue LED flashes.
Example: #, 8-7-6-5-4-3-2-1
●
, 0-6
●
, 1-2-3-4-5-6-7-8
●
, 1-2-3-4-5-6-7-8
●●
Result: A new Sub-Master Code, 1-2-3-4-5-6-7-8, is activated and the prior Sub-Master
Code is deleted.
5.2.2
Changing the Code Lock User Code
o
NOTE: To program the Code Lock, the lock must be in the open position with the #
button visible and the door to the 16
N
1
®
should be open.
5.2.2.1
To Change the User Code Using the Sub-Master Code
1.
Press the red “#” button located under the Code Lock handle (see Figure 2).
2.
Enter the current Sub-Master Code and verify a 1 second blue LED flash.
3.
Enter 0-7 and verify a 1 second blue LED flash.
4.
Enter the new four (4) digits User Code and verify two 1 second blue LED flashes.
Example: #, 8-7-6-5-4-3-2-1
●
, 0-7
●
, 1-3-1-3
●●
.
Result: The Code Lock User Code is set to 1-3-1-3.