Medic Therapeutics UVC DISINFECTION LAMP User Manual Download Page 2

 ATTENTION

The ultraviolet lamp must be used when NO ONE is present, to avoid the 
harm of direct exposure to the UVC light. Do NOT expose your eyes or skin 
to the UVC light.

PRODUCT FEATURES

Metal housing:  

Anti-oxidation Metal Base

Simple Operation:  

3 Disinfection Timers

Wireless Remote Control Operation:   Operates through the Wall
No Ozone / With Ozone Operation:   High-Purity Quartz Lamp

PRECAUTIONS FOR USE

1.  During the use of this product, the surface of the ultraviolet lamp should 

be kept clean. If there is dust or oil on the surface of the lamp, it should 
be wiped in time to avoid affecting the sterilization effect.

2.  When cleaning indoor air with ultraviolet lamps, the room should be 

kept clean and dry to reduce dust and water vapor. When the indoor 
temperature is lower than 20C° or higher than 40C°, the irradiation  
time should be extended accordingly.

3.  The ultraviolet lamp must be used when no one is around. Do not look 

directly at the ultraviolet light source and do not expose your skin to it.

4.  This UVC lamp should be used accordingly with the approximation of 

1w/m. This product is suitable for the disinfection and sterilization of 
rooms within 36-60 m. If the objects and garments are being sterilized at 
a close range, the sterilization time should not exceed 15 minutes.

5.  If there is artwork, calligraphy or paintings in the sterilized space that 

require shading, please cover them with a cloth or paper during use.

6.  After the use of the sterilizing lamp, it should be stored well to avoid 

damage and personal injury caused by the improper use of the lamp.

REMOTE CONTROL INSTRUCTION

INSTRUCTIONS FOR USE

Online Remote Control  Human Body  

Detection Safety Design

1.  First plug in the lamp to a power source and then turn on the online 

switch on the remote and walk away.

2. Press the ON/OFF button on the remote control.
3.  Select the corresponding disinfection time (15 min /30 min /60 min), and 

the power indicator will flash at the same time as the corresponding time 
indicator.

4.  After pressing the corresponding time on the remote control, the lamp 10 

second delay will be start. When the person walks into the lamp’s sensor 
range of 1.5m, the lamp will turn off; the lamp will then restart within 10 
seconds after the person has walked away and continue to operate until 
the scheduled disinfection time has been completed.

ON/OFF

15 min time switch

60 min time switch

30 min time switch