   To set a static IP address on the 782-AV, use an IR or Bluetooth remote control to show the on-screen setup menus. 

Press the menu (or home) button to show the Media list and then use the arrow up cursor key to show the setup 

menus. Navigate to the Advanced/Configuration-Configure Network-IP address setting menus to set the IP address 

details. Ensure that all static IP address details (netmask, gateway etc.), are in accordance with the settings  

provided by the network system administrator.

7.   Once the 782-AV is connected on the network, its advanced configuration options may be setup using a networked 

computer running a standard web-browser. In the web browser (Internet Explorer, Chrome, Firefox, Safari) enter 

the IP address of the 782-AV into the navigation address bar. The browser will then show the configuration web 

pages from the 782-AV unit, starting with the specification page. The main configuration web pages can be  

accessed by clicking on the menu link on the left hand side of the screen. Context sensitive help is shown on the 

right hand side in case further help is required with setup.

  It is recommended that the following (minimum) settings are configured at time of installation:

  a)   Unit name (in Operating Mode menu) – This should reflect the physical location of the unit, preferably in line 

with a system wide naming convention. This name of the unit will be shown in the Media Manager software.

  b)   Date/Time – For most accurate timekeeping, configure the unit to use a corporate or internet NTP time server  

(a commonly used internet time server is pool.ntp.org). If this is not available, set the date and time manually. 

The date/time will be retained and updated throughout a power outage of up to 3 days.

8.   The media accessible on the display is controlled from the Media Manager software. When the Media Manager 

server software is installed and running, it should automatically detect a new 782-AV unit and create a new ‘icon’  

for it. Media can then be assigned to the 782-AV by ‘dragging and dropping’ live streams, stored files etc. onto the 

782-AV icon. The 782-AV will then be instructed to download or access the specified media and start showing it  

on the display as requested by the user.

  If the 782-AV is not automatically recognised by the Media manager software, then:

  a)   Use a browser to go onto the 782’s web page menus, and enter <MM server IP address>/MediaManagerUp-

dates/config (without < or >) into the Config File Location field and click on Apply. Creating this direct connection 

to the Media Manager server should cause the 782’s icon to be created. The network connectivity from the  

782-AV to the Media Manager server can be checked by checking the ‘Check update locations’ tick box and 

pressing the apply button.

  b)   In Media Manager, manually create a 782-AV icon, by right-clicking on the workspace and selecting the Create/ 

Endpoint/782-AV option. This allows the IP address of the 782-AV to be manually specified, so Media Manager 

can then try and connect directly to the 782-AV unit.

   It is essential for the 782-AV to be able to communicate with a Media Manager server to be able to initially  

configure or then change the user selectable media.

MediaStar 782-DS Digital Media Player

Quick Start Guide

782-AV 4K UHD Digital Signage Player 

200-2440 V3

3/8

Summary of Contents for 782-AV

Page 1: ...r the third prong is provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet 8 Protect the power cord from being walke...

Page 2: ...location Only the LPS Limited Power Source power supply provided with this equipment should be used This device must be installed using a mains AC supply plug and socket that is located near the equip...

Page 3: ...nternet time server is pool ntp org If this is not available set the date and time manually The date time will be retained and updated throughout a power outage of up to 3 days 8 The media accessible...

Page 4: ...ation and external audio mute This 3 5mm jack connector is physically labelled IR blaster and the electrical pin out is available on request Date Time Configure the local time to use a Network NTP ser...

Page 5: ...1 x USB2 1 x USB3 USB2 500mA USB3 150mA or 900mA when connected to 802 3at PoE or 3A AC mains adapter Mouse Keyboard HID compatible USB memory keys used for local media load and secure software upgra...

Page 6: ...Notes MediaStar 782 DS Digital Media Player Quick Start Guide 782 AV 4K UHD Digital Signage Player 200 2440 V3 6 8...

Page 7: ...t Immunity characteristics EN61000 3 2 2014 Electromagnetic compatibility Limits for harmonic current emissions EN61000 3 3 2013 Electromagnetic compatibility Limitation of voltage changes voltage flu...

Page 8: ...To prevent possible harm to the environment or human health from uncontrolled waste disposal please separate these items from other types of waste and recycle them responsibly to promote the sustaina...

Reviews: