medi Circaid Juxtafit Essentials Quick Start Manual Download Page 2

If further assistance is required, please contact Customer Service by phone at (800) CIRCAID (247-2243) or by email at [email protected]

 

 

We recommend you apply any necessary finger dressings before applying the Armsleeve.

1.  AlIgn ARMSlEEVE

Slide the armsleeve all the way up to the underarm. Ensure that:

•  The thin elastic material running down the center of the armsleeve 

rests against the inside of the arm and elbow crease. The widest  

portion of the thin material is centered at the elbow crease.

•  The seam on the back of the armsleeve should run along the back 

side of the arm. (The sleeve may feel tight initially. Slide sleeve on 

and off to loosen.)

•  If wearing a hand piece, don the hand piece. If wearing a Juxta-Fit™ Glove or  

Gauntlet see their Directions for Use.

2.  fAStEn tHE BAnDS

•  Disengage the armsleeve band closest to the wrist. Pull the band up and across  

the thin elastic material on the inside of the arm and fasten the hook to the  

opposing side with firm and comfortable compression.

•  Detach the second band and do the same, this time pulling the band in the  

opposite direction as the first and attach with firm and comfortable compression.  

Do the same with the remaining two bands on the forearm, alternating the  

direction in which the bands are pulled.

•  If using the elbow band, pull it up and across the thin elastic  

material and attach to the opposing side of the elbow with firm 

and comfortable compression. The position of the elbow band 

may need to be adjusted to maximize comfort and ensure that  

no gaps are present between the bands.

•  Attach the remaining top two bands with firm and comfortable 

compression. Ensure that the hook tab on the top most band is 

completely covered and will not rub the skin or cause discomfort.

3.  APPlyIng tHE CoMfoRt CoVERuP™ (oPtIonAl)

•  Ensure that all tab ends of the armsleeve are securely fastened to the garment. 
•  Slide the Comfort CoverUp™ over your compression garment. 
•  Fasten the hook tabs of the Comfort CoverUp™ to the armsleeve.

4.  REMoVAl

•  Starting from the top, detach each of the tab ends and fold the bands back onto themselves. This will 

help make reapplication easy and aid in keeping the hook tabs from collecting lint and catching on 

other materials.

•  Do the same with the bands on the gauntlet/glove and slide the hand piece off the hand.
•  Slide off the armsleeve. Once complete, it should resemble its starting position.

5.  AlIgn ElBow BAnD (oPtIonAl) 

The elbow band will be pre-applied in its proper position for ease of use, however some adjusting to 

maximize comfort and coverage may be needed. If the elbow band is removed and needs to be reapplied:

•  Locate the widest point at the elbow.
•  Apply the elbow piece, placing the two hook tabs 1cm away from the medial edge of the  

widest elbow point. Ensure that the hook is not making contact with the thin elastic material,  

and the two short tabs should be set with one above, and one below the center of the elbow.

•  The band should be oriented so that it can be pulled across the thin elastic material and  

connected to the other side.

•  Use of the elbow band will assure continuous compression throughout the entire arm. However,  

if additional mobility is needed within the elbow region, the elbow band may be easily removed  

for increased flexibility. 

Note: The elbow band is symmetrical, so either end may be used for alignment.

StEP 1:

 Locate the BPS™ card in your packaging. 

StEP 2:

 Starting with the bottom band, line up the pressure guide line on the garment 

 with the line on card marked with 

StEP 3:

 Note where the second pressure guide line on the garment is in relation to the 

 correct color coded pressure range on the card. (Fig. A, B, and C) 

StEP 4:

 If the pressure guide line on the garment either falls short (Fig. B) or goes beyond the correct pressure range (Fig. C), 

 readjust the band as necessary so the second guideline is aligned with the prescribed pressure range (Fig. A). Completely 

 loosen band before reapplying if too much tension has been applied.

StEP 5:

 Repeat BPS™ Steps 2-4 for each band going up the arm. Be sure to adjust to the SAME tension on the BPS™ card scale as 

 the bottom band. Bands may need adjusting throughout the day to maintain the prescribed pressure range.

REmEmbER:  

The Juxta-Fit™ Armsleeve should never hurt. It should feel firm but comfortable. If pressure 

increases or decreases noticeably during wear, loosen or tighten any bands. Always ensure, however, that 

the correct prescribed pressure range is being applied. Slightly loosen the bands of the armsleeve for 

night time wear. Each set of vertical guidelines may be at a different location on the arm depending on 

the size and shape of the arm. They do not need to be aligned down the front center of the arm or in any 

other specific location on the arm. 

If EXPERIEnCIng Any PAIn, IMMEDIAtEly REMoVE  

tHE ARMSlEEVE AnD ConSult youR PHySICIAn.

~

 

fig. A

 Correctly Adjusted for 20-30mmHg

~

 

fig. b

 Not enough tension for 20-30mmHg

~

 

fig. C

 Too much tension for 20-30mmHg,

 

Set to 

Align Armsleeve

Fasten 1st Band

Fasten Remaining Bands

Finished View

Align 

Elbow 

Band

DIRECTIONS FOR USE

Pull bands to firm and comfortable  
compression, or if directed by a  
Healthcare Professional, follow  
steps below to set compression  
to the prescribed level.

uSIng tHE BuIlt-In PRESSuRE SyStEM™ (BPS™): 