Main Menu 

 

 

 

 

To display the Main Menu, press the 

Menu

 button on the front panel. Then you can use the 

Next

 

and 

Back

 buttons to navigate through the submenus. Use the 

Select

 button to make a choice. 

 
The submenus to the Main Menu are: 

 

Setup:

  Use this menu to set the clock, language preference, and input options. You can 

also use this menu to turn on and configure the “Patient Information” feature. This feature 
allows you to enter patient information at the start of each imaging session. Using this 
feature requires a USB keyboard (available as an option). 

 

Image Options:

  Use this menu to select the format and resolution of images. 

 

Advanced:

  Use this menu to select advanced options. You can also view all of the current 

settings and reset them to factory defaults. In addition, you can upgrade your USB170 to 
add options and features (requires a special "upgrade USB flash drive" available from 
MediCapture). 

 

Exit:

  Selecting Exit returns the USB170 to live mode so you can capture images. This 

option is the same as pressing the 

Menu

 button on the front panel. 

These submenus are described in the following sections. 

Summary of Contents for MediCap USB170

Page 1: ...MediCap USB170 Medical Still Image Recorder User Guide USB170 UG01 EN 130812 MC...

Page 2: ...CLASS A This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection...

Page 3: ...being walked on or pinched especially near plugs outlets and the point where the cord exits from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only with a cart...

Page 4: ...9 Capturing Images 9 Reviewing Images 10 Creating Patient Folders 11 Using the Menus 11 Main Menu 12 Setup Menu 13 Image Options Menu 14 Advanced Options Menu 14 Transferring Images To Your Computer 1...

Page 5: ...nect your monitor directly to your video source then connect the USB170 to the secondary output on your video source or use a Y Splitter not included Ordering Information MediCapture recommends MediCa...

Page 6: ...MediCap USB170 User Guide English 6 of 20 USB170 UG01 EN 130812 MC Front Panel Back Panel...

Page 7: ...Splitter not included The unit is for exclusive interconnection with IEC60601 certified equipment in the patient environment and IEC 60XXX certified equipment outside of the patient environment A cer...

Page 8: ...SB170 9 Insert the flash drive in the USB connector of a Windows or Apple computer or laptop 10 On your Windows or Apple computer navigate to the USB drive labeled MediCapture You can then access the...

Page 9: ...es If your camera or monitor uses RCA connectors you will need to obtain a BNC to RCA adapter Some USB170 models ship with this adapter Inserting a USB Flash Drive Before you begin using your USB170 i...

Page 10: ...ession Simply press the Back and Next buttons on the front panel This will step you through the images Select Back Next and Delete buttons are used for reviewing images After you review the images you...

Page 11: ...ed via the Menus Press the Menu button to display the Main menu You can scroll through the menu choices using the Back and Next buttons on the front panel Use the Select button to make a choice Select...

Page 12: ...o enter patient information at the start of each imaging session Using this feature requires a USB keyboard available as an option Image Options Use this menu to select the format and resolution of im...

Page 13: ...the front panel Power button Language Use this menu to select your language preference for the menus Input Options Use this menu to select the video input type S Video or Composite BNC and the video...

Page 14: ...to upgrade the firmware on your system This allows you to add new features and options to your USB170 To use the upgrade option you must insert a special upgrade USB flash drive in the front panel Con...

Page 15: ...contact In other words if you have other types of switches that operate using a closed contact you can also plug them into the footswitch connection and use them to trigger an image capture For examp...

Page 16: ...ng saved Therefore it is recommended that you normally set Anti Blur to Off Only set this option to On if it is necessary to eliminate a blurry effect from movement Patient Information Feature This fe...

Page 17: ...ddition if you are capturing images in the DICOM format as selected in the Image Options menu page 14 you can view the patient information in the DICOM header of each image To view the DICOM header on...

Page 18: ...l be displayed on your computer just like any other drive You can then drag and drop recorded images from the USB170 drive across the network onto your computer s drive To connect the USB170 to a netw...

Page 19: ...s available as an option Standard 3 5mm mini jack Mechanical Size 240 x 200 x 63mm 9 5 x 7 9 x 2 5 Weight 1 7kg 3lb 12oz Environmental Storage and transportation 40 to 85 C Operating 20 to 40 C Power...

Page 20: ...FOREGOING YOU ASSUME ALL RISK AND LIABILITY FOR LOSS DAMAGE OR INJURY TO YOU AND YOUR PROPERTY AND TO OTHERS AND THEIR PROPERTY ARISING OUT OF USE OR MISUSE OR INABILITY TO USE THE ABOVE LISTED PRODUC...

Reviews: