Erase memory
(Performing an erase will remove all learned transmitter codes from your Vibra-Call 3)
With the Vibra-Call 3 receiver in the Docking Port press and hold the learn button on the Docking port.
(see photo on page 2)
Hold down the program button and the receiver will vibrate once. Continue to hold down the button.
After 4 seconds the receiver will initiate 2 short vibrations, continue holding the program button and after
another 6 seconds the receiver will initiate 3 short vibrations.
Release the program button and all previously learned transmitter codes will have been successfully erased.
Programming
(If you are using a smoke detector or fire transmitter with the Vibra-Call 3 you
must program these transmitters
first
or the supervision will not operate.)
On the rear of the Docking Port is a programming button used to program the Medallion Series MC 418 MHz
transmitters to the Vibra-Call 3 receiver. With the Docking Port power switched on, and the Vibra-Call 3 placed in
the Dock:
Press and hold the program button located at the back of the Docking Port case. The Vibra-Call will
vibrate once, pause for approximately 5 seconds and then vibrate twice. The unit is now in program mode.
Release the program button and the unit will remain in program mode for approximately 30 seconds.
While in program mode, the receiver will memorize the code of the transmitter and then exit program
mode.
While the receiver is in program mode, press the button on any Silent Call Medallion Series MC 418 MHz
corresponding type transmitter. When the receiver receives the transmitted signal, it will memorize the
code, and exit program mode automatically.
Remove the Vibra-Call 3 from the Dock, activate the transmitter previously programmed and the receiver
will vibrate as indicated by the Alarm Reference Chart.
Optional Accessories
Optional accessories for the Vibra-Call 3 receivers include:
3 pack of protective rubber skins –Model # Skins
Replacement leather Pouch-Model # LP-12
Product Specs
Frequency: 418 MHz
Main Power: Input AC 120v Output 17.2VDC 0.8A, 13.7W
Port Battery Backup: 12 VDC, 350 mAh
Receiver Batteries: (2) AAA rechargeable Batteries
Current Draw: Idle 15 mA, Alert Condition – all alert mechanisms active 150 mA.
Technical Support
For technical support on this or any other Silent Call product, please feel free to contact us. You can reach us at our
toll free number phone at 800-572-5227 (voice or TTY) or by Email at [email protected].