MedaCure Comfort Zone LRM36 User Manual Download Page 14

 

FEATURE 

PUMP 

Power supply 

120V/60

,

Hz

 

V/50Hz

230

 

Power 

18

Fuse rating 

500m

A/250V 

Pressure 

30

mmhg

6

~ 0mmhg 

Dimensions 

1.4

1

 

” (L) x

12.2

 

” (W) x

6

  ” (H) 

Weight 

8.6

 lbs. 

Environment 

temperature 

Operation: +1

°

0

 

C

 

 

/+4

°

0

 

C

 

Storage: -1

°

5

 

C

 

 

/+5

°

0

 

C

 

Shipping: -1

°

5

 

C

 

 

/+7

°

0

 

C

 

Environment 

humidity 

Operation:10%-90% 
non-condensing 

Storage:10%-90% 

non-condensing 

Shipping:10%-90% 

non-condensing 

Atmospheric Pressure 

Operation: 700-1013,25 hPa 

 

 

FEATURE 

MATTRESS 

Dimensions 

 
80” × 36” × 10” 
 

Cell height(inflated) 

8” 

Air cell material 

TPU 

Cover material 

PU  

Elements number 

1

2  cells 

Max weight 

50

4

 lbs. 

Weight 

9

2  lbs. 

 

13

 

 
 
 
 
 

 

 

Pump Control Unit 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

Mattress 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for Comfort Zone LRM36

Page 1: ...User Manual FOR MODEL LRM36 2017 MADE IN CHINA...

Page 2: ...NG AND DISINFECTION CONDITIONS OF DISPOSAL General conditions of disposal SPARE PARTS ACCESSORIES TROUBLESHOOTING ELECTROMAGNETIC COMPATIBILITY DECLARATION TECHNICAL FEATURES WARRANTY page 2 page 2 pa...

Page 3: ...ny questions please contact your dealer for advice and assistance INTENDED USE The Comfort Mattress Zone is designed for bed sore and wound care therapy treatment and prevention which may occur during...

Page 4: ...without first completely reading and understanding this instruction manual If you are unable to understand the warnings cautions or instructions please contact a healthcare professional dealer or aut...

Page 5: ...or the lit Ventilation operating is function Loss Air Low Self Turning or Function Rotation Lateral Rotation When LED the s i the lit Rotation function is on 1 Right equals Cycle Full turn and Left tu...

Page 6: ...male quick connector 5 Protective cap of connector 6 Fuse 7 Sealing ring 3 6 10 9 Back 8 Filter 9 Main filter 10 Protective cap of filter 11 Hook 11 8 4 1 2 3 1 Pillow 2 Cover 3 Fixing belt 4 Low air...

Page 7: ...ttention to air hoses connector WARNING Make sure the pump unit is suitable for the local power voltage Do not position the equipment so it is difficult to disconnect the plug USER 1 It 2 3 Do technic...

Page 8: ...it into the ground power supply 7 Do not use the product in case of the following 1 the plug or the cable is damaged 2 the system sounds abnormal or vibrates intensely 3 the control unit fell on the f...

Page 9: ...io n please contact your local agent directly They might require a technician to take care of the problem No Lights on Pump Unit Check that control the unit is connected to the mains power supply and...

Page 10: ...emissions CISPR 11 Group 1 The device uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment...

Page 11: ...s to line s 2kV line s to earth 1kV differential mode 2kV differential Mains power quality should be that of a typical commercial or hospital environment Voltage Dips short interruptions and voltage v...

Page 12: ...as determined by an electromagnetic site survey should be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked with the following symbol...

Page 13: ...wer of transmitter W Separation distance according to frequency of transmitter m 150 kHz to 80 MHz d 1 2 P 80 MHz to 800 MHz d 1 2 P 800 MHz to 2 5 GHz d 2 3 P 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1...

Page 14: ...0 C Storage 1 5 C 5 0 C Shipping 1 5 C 7 0 C Environment humidity Operation 10 90 non condensing Storage 10 90 non condensing Shipping 10 90 non condensing Atmospheric Pressure Operation 700 1013 25...

Page 15: ...e of the defect and if the product is serialized indicate the serial number DO NOT return products to MedaCure without prior consent Please obtain a return authorization number from MedaCure C O D shi...

Reviews: