![Med Food GHIACCIO 30 User Manual Download Page 18](http://html1.mh-extra.com/html/med-food/ghiaccio-30/ghiaccio-30_user-manual_1759216018.webp)
-18-
SAFETY THERMOSTAT
RESET BUTTON
GHIACCIO 120 -
180
TANK CLEANING
For cleaning operation of the tank proceed as follows:
1)
Remove the product from the tank.
2)
Switch off the unit using main switch (see control panel) and unplug the unit.
3)
Before cleaning the tank the inside temperature must be the same as the ambient.
4)
Clean the tank; don’t use too much water that could damage the motor fans; rinse and dry carefully.
5)
Turn the unit on, with the night curtain (if present) lowered and 1 hour later you can load the product again.
Warning! Do not use water jets for cleaning: this can damage the electrical
parts.
Warning! Do not use mechanical appliances or other means to speed up the
defrosting process, other than those recommended by the manufacturer.
AUTOMATIC DEFROSTING
APPLIANCES USING R404a COOLING FLUID
On theese appliances
the defrosting is automatic
.During the defrosting period, the resulting water
is collected into a stainless stell tray and dispelled by an automatic electrical evaporating system. In
case of fault the security thermostat breaks the voltage to the electrical resistance, and the water brims
on the floor;
call the operator
, who must reset the thermostat stud only after having eliminate the
cause of the fault.