background image

 

                                                                                       

 

 

 

  16

16

16

16  

 

 

 

9. CHECK AND MAINTAIN

 

 

Warning 

 Check and maintain the game by technicians.   

Please power off the game when check and maintain.   
Please do not put any tools into cabinet, otherwise it will cause problem.   
After checking, please tightly screw the screws and close the door.

 

 

 

 

 

 

Daily Check

 

ITEM

 

DESCRIPTION

 

COIN MECH 

Check whether the coin mech work properly. 

MONITOR 

Check if the monitor works properly. 

SOUND 

Check whether the sound and volume are ok. 

PUMP 

Check if the pump works properly.

 

TEMPERATURE 

HUMIDITY 

Check if the temperature and humidity is proper 

 

 

Daily Maintenance 

 

 

 

ITEM

 

DESCRIPTION

 

Periodically 
check

 

PUMP 
INTERFACE 

Check all the interfaces of the pump to see 
if there is water leakage 

Every 3 
months 

WATER 

Check if the water is clean, if not, please 
change the water. 

Every 2 

weeks 

ITEM

 

DESCRIPTION

 

THE CABINET 

Clean the cabinet with water and soft paper. 

MONITOR 

GLASS 

Clean the monitor and glass with water and soft 
paper.   

PCB 

Sweep  the  dust  and  dirty  in  the  board  with 
small brush 

Summary of Contents for Kiddie Firemen

Page 1: ...Kiddie Firemen Operation manual...

Page 2: ...game door unless maintenance or parts replacement is required 2 Please switch off the power before checking and maintenance 3 Please switch off the power before opening the game door 4 Fire extinguish...

Page 3: ...kage 3 To put the machine to normal operating please properly adjust the coin match and the game settings when use at the first time 4 Please regularly check all the functions of the game when operate...

Page 4: ...t use the following cleanser Alterative Cleanser Acidic Cleanser Insecticide sterilized water alcohol or other chemical cleanser Notes of Moving and Shipping 1 Properly disassemble the game for necess...

Page 5: ...ene such as water cannons water tank and fire extinguisher 4 Game over when the playing time countdown to 0 2 TECHNICAL PARAMETER VOLTAGE AC 220V 110V 50 60HZ MAX CURRENT 8A 15A Note please refer to t...

Page 6: ...ation to leave the ground about 5mm WARNING Please power off the game first and pull out the cord then move the game Please do not carefully move turnover transport the game otherwise it will destroy...

Page 7: ...men in the same type of Kiddie Ride with monitor then select the concrete placement machine according to the machine s exterior 2 Choose the proper location for installation please follow the below dr...

Page 8: ...7 7 4 2 FIX THE FOUNDATION Screw the foundation down to hold the game distance between ground and wheel is 1cm 4 3 ADD WATER As shown below Add about 50L clean water 1cm Foundation Wheel Add water he...

Page 9: ...the both ends for GND is more than 100 megohm 4 Connect the wires Attention A Please make sure the power cord is not pressed by wheel foundation etc Otherwise it will damage the wire to cause short ci...

Page 10: ...please switch on the game 3 Inserting coin to check if the coin machine cans work properly 4 Visually check the game and confirm the display and light can work properly 5 Enter into the setting progr...

Page 11: ...sually check the game and confirm the display can work properly 3 Check the sound if it is ok 4 Confirm the coin mech button and the squirt is working properly Warning Before operation please confirm...

Page 12: ...G 1 Find out the setting board KEYS FOR SETTING TEST Enter into the setting menu or skip to the next menu ENTER Change the setting SERVE 1 free play Setting board SW1 TEST SERVE SELECT ENTER ERASE Set...

Page 13: ...how many scores to get 1 ticket Standby music this setting decides if play music when the game is standby Ticket out this setting can decide if to payout ticket not opened yet Volume this setting is...

Page 14: ...tentiometer is not working properly P1 up and down potentiometer this item is to test the up and down potentiometer When move the squirt gun up and down the value will change if it is not change it me...

Page 15: ...he adjusting switch of COIN Signal wave length to 50MS 5 Adjust the micro adjusting resistance of token tolerance Clockwise increasing the sensitivity of token tolerance that is the range of accepting...

Page 16: ...entiometers are working properly but the squirt coordinate is not accurate please select P1 coordinate correction to correct it 4 When the coordinate at the upper left corner move the squirt gun to th...

Page 17: ...erly SOUND Check whether the sound and volume are ok PUMP Check if the pump works properly TEMPERATURE HUMIDITY Check if the temperature and humidity is proper Daily Maintenance ITEM DESCRIPTION Perio...

Page 18: ...gulating valve 1 then the pump is energized and run and drain the water to the bucket 3 After drained the water please close the drain value and add clean water 50 L to the game 4 Open the water press...

Reviews: