Transmitter mag-flux M1

Connection  of  the  sensor 

mag-flux 

S  and  the  flow  probes 

mag-flux

 MIS 

These  sensors  are  equipped  with  a  pre-assembled  cable  ex-
factory. This cable is permanently connected to the sensor at one 
end.  The  end  leading  to  the  transmitter  is  fitted  with  a  cable 
gland and pre-prepared cable ends for connection. The attached 
wire numbers serve for orientation. 

 

Fig 18 

Connections of the sensor 

mag-flux

 S and the probes 

Anschluss HART

®

 

A  number  of  options  are  available  for  HART

®

  communication. 

However, for all these options  loop resistance must be  less than 
the  maximum  load  specified  in  Chapter  „Outputs“  (see  page  6). 
The  HART

®

-Interface  is  connected  via  terminals  8  and  9  of  the 

(active) current output.  
The minimum load impedance is 250Ω. 

 

 

Fig 19 

Electrical connection for HART

® 

communication, schematic diagram 

Display and operator interface (basic version) 

Zero point adjustment 

Below  the  mains  transformer,  next  to  the  lights  and  the  data 
storage  module  (DSB),  there  is  a  switch  for  adjusting  the  zero 
point.  In  order  to  reach  the  switch,  the  transducer  must  be 
opened  by  unscrewing  the  front  cover  and  removing  the 
decoration foil.  
For  processing  the  zero  point  adjustment  please  observe  the 
advices in Section “Zero point calibrationon” on page 4. 
 

 

Fig 20 

Switch for zero point adjustment  

 

LED display 

The  actual  operating  status  information  of  the 

mag-flux  M1

  is 

displayed by three LED for the basic version: 
 

 

Fig 21 

Status-LED of the 

mag-flux M1

 (basic version) 

off 

Not powered 

green LED 

flashing 

Power on 

off 

Flow direction forward 

yellow LED 

on 

Flow direction reverse 

off 

Normal operation 

flashing 

Limit exceeded 

red LED 

on 

Malfunktion 

Summary of Contents for mag-flux M1

Page 1: ...a later time will not be honored II Warranty Your flowmeter was manufactured in accordance with the highest quality standards and was thoroughly tested prior to shipment However in the event any prob...

Page 2: ...re to be used MECON GmbH accepts no liability for any loss or damage of any kind arising from improper operation of any product improper handling or use of any replacement part or from external electr...

Page 3: ...trical devices device installation and process tech nology when replacing the transmitter elec tronics The highly integrated electronic com ponents of the device are ESD sensitive Caution The complete...

Page 4: ...bes In order to be able to calculate the volume flow when using the mag flux flow probes correctly from the measured flow velocity the installation requirements must be kept regarding position and mou...

Page 5: ...e operates the empty pipe detection Insulation coatings on the electrodes surface worse the empty pipe detection Data memory chip DSM The replaceable data memory chip DSM is an EEPROM device in DIL 8...

Page 6: ...HART Volume flow or flow speed Using the HART protocol the current output has to be assigned to volume flow in the mode of 4 20mA Pulse Frequency output Pulse duration adjustable range is 0 1 2000 ms...

Page 7: ...ds to be mounted separately from the sensor if the mounting area is difficult to access there is a lack of space medium and ambient temperatures are extremely high there is strong vibration Fig 6 Prop...

Page 8: ...ss conditions Fluid temperature The data sheet rating plate of the connected transmitter is binding With directly mounted transmitter on the sensor compact version the heat entry from the process to t...

Page 9: ...coil cable as shielded twisted pair In order to protect the cable from ex ternal interference the twisted pair wires are covered by an additional overall shield Cable length wire cross section Example...

Page 10: ...spectively For terminal assignments see Electrical terminals on page 9 Caution Do not connect or disconnect the field coil cable before the primary power of the meter has been disconnected Please obse...

Page 11: ...terface is connected via terminals 8 and 9 of the active current output The minimum load impedance is 250 Fig 19 Electrical connection for HART communication schematic diagram Display and operator int...

Page 12: ...ry the display board inside the electronic compartment by loosing the three thread bolts 4 Unplug the green connector on the power supply board 5 Screw out the 3 thread bolts and after that extract th...

Reviews: