Mechatronics Eurosens Delta CAN 250 Operation Manual Download Page 11

EUROSENS

 

Fuel

 

flow

 

meters.

 

Operation

 

manual.

 

ver.

 

1.6

 

 

www.mechatronics.by

                              

 

 

 

          

Page

 

11

 

|

 

30

 

 

2.8.

 

Flow

 

meter

 

design

 

and

 

operation

  

2.8.1.

 

Operation

 

principle

 

The

 

flow

 

sensor

 

measures

 

the

 

amount

 

of

 

fuel

 

flowing

 

through

 

the

 

measuring

 

chamber.

 

Pressurized

 

fluid

 

coming

 

through

 

the

 

inlet

 

nozzle

 

flow

 

sensor

 

in

 

the

 

inlet

 

of

 

the

 

measuring

 

chamber,

 

the

 

piston

 

slides

 

along

 

the

 

inner

 

surface

 

of

 

the

 

chamber

 

and

 

simultaneously

 

slides

 

along

 

the

 

jumper.

 

The

 

piston

 

displaces

 

fluid

 

enclosed

 

in

 

it

 

inside

 

and

 

outside

 

of

 

the

 

piston

 

chamber

 

through

 

its

 

outlet

 

to

 

the

 

outlet

 

port

 

(see.

 

Fig.1).

  

The

 

enclosure

 

provides

 

the

 

orientation

 

of

 

the

 

rotation

 

axes

 

of

 

the

 

cover

 

pin

 

with

 

the

 

magnets

 

and

 

the

 

hub

 

of

 

the

 

piston,

 

thanks

 

to

 

the

 

number

 

of

 

dimensions

 

of

 

the

 

cover

 

and

 

the

 

housing

 

which

 

provides

 

the

 

optimum

 

rotation

 

of

 

the

 

ring

 

chamber.

  

During

 

one

 

rotation

 

of

 

the

 

piston

 

volume

 

of

 

liquid

 

equal

 

to

 

the

 

volume

 

of

 

chamber

 

is

 

displaced.

 

In

 

this

 

case,

 

the

 

electronic

 

position

 

sensors

 

generate

 

pulses

 

as

 

the

 

turnover

 

of

 

the

 

piston,

 

which

 

are

 

transmitted

 

to

 

the

 

electronic

 

control

 

unit

 

for

 

the

 

selected

 

interface.

 

 

Fig.

 

1.

 

EUROSENS

 

measuring

 

chamber

 

operation:

 

1

 

 

inlet,

 

2

 

 

outlet,

 

  ‐ 

fluid

 

is

 

entering

 

the

 

measuring

 

chamber,

 

  ‐ 

fluid

 

in

 

measurement

 

process,

 

 ‐ 

fluid

 

is

 

going

 

to

 

leave

 

the

 

measuring

 

chamber.

 

 

2.8.2.

 

Operation

 

modes

 

Table

 

8

 

 

Flow

 

meter

 

modification

 

Flow

 

rate,

 

l/hour

 

Interference

 

eurosens

 

XYZV,

 

где 

Y(max.

 

flow

 

rate)=

 

       

l/hour

 

Normal

 

flow

 

rate

 

Q

0

 

<

 

Q

 ≤

Q

max

 

Tampering

 

 

The

 

impact

 

of

 

constant

 

magnetic

 

field

 

for

 

more

 

than

 

10

 

seconds

 

Idle

  

Normal

 

operation

 

 

Overload

 

 

        

100

 

<

 

2

 

   

2

70

 

70

100

 

>

 

100

 

Attempts

 

are

 

fixed

 

        

250

 

<

 

5

 

   

5

200

 

200

250

 

>

 

250

 

        

500

 

<

 

10

 

  

10

400

 

400

500

 

>

 

500

 

Summary of Contents for Eurosens Delta CAN 250

Page 1: ...phone 375 1771 7 13 00 e mail office mechatronics by Eurosens flowmeters operation manual...

Page 2: ...selection 5 2 5 Dimensions 6 2 6 Specification 6 2 7 Contents of package 10 2 8 Flow meter design and operation 11 3 WARRANTY 15 4 INSTALLATION RECOMMENDATIONS FOR EUROSENS FLOWMETER 16 4 1 Visual ins...

Page 3: ...their operating features The sources of danger during the installation and operation of the flow sensors are electrical current and working fluid which can be pressurized to 2 5 MPa and have temperat...

Page 4: ...nnormalized pulse only for Direct possible 100 No symbol LCD is not installed Direct 1 PN normalized pulse No symbol not possible 250 232 normalized pulse RS232 interface 500 485 normalized pulse RS48...

Page 5: ...with the safe operation of the Eurosens sensors on petrol engines are assigned to the installer of the equipment Fuel flowmeters Eurosens Direct Delta N RS is a unique equipment that allows to set ind...

Page 6: ...commended to install the flowmeter when there is an air in the supply or return line and also in the fuel system with high capacity pomp when the fuel consumption is not large 2 5 Dimensions See para...

Page 7: ...easure not only the fuel consumption but also the derived parameters the engine is running boiler the fuel consumption and the operating time in different modes during the handling etc These parameter...

Page 8: ...50 1 5 Delta PN A 100 I 0 5 10 50 100 200 1 2 Delta PN A 250 I 0 5 20 125 250 100 1 2 Delta PN A 500 I 1 0 40 250 500 50 1 5 Flows to supply consumption in liters hour 45 10 90 20 160 30 A autonomous...

Page 9: ...lta CAN 250 0 5 20 125 250 100 1 2 Delta CAN 500 1 0 40 250 500 50 1 5 Delta CAN 100 I 0 5 10 50 100 200 1 2 Delta CAN 250 I 0 5 20 125 250 100 1 2 Delta CAN 500 I 1 0 40 250 500 50 1 5 Flows to suppl...

Page 10: ...5 Vibration resistance Max acceleration to 100 m s2 in the frequency range from 5 to 250 Hz Resistance to aggressive environments Oil and petrol resistance Electromagnetic compatibility ECE Regulation...

Page 11: ...number of dimensions of the cover and the housing which provides the optimum rotation of the ring chamber During one rotation of the piston volume of liquid equal to the volume of chamber is displace...

Page 12: ...eat volume of return chamber l Return flow rate l h Temperature in return chamber C Battery charge Firmware version These parameters plus some additional are also displayed in configuration software o...

Page 13: ...ave holes for sealing that allows to determine the facts of unauthorized interference in the fuel system after the installation of the flow sensor 2 8 5 Characteristics of the pulse signal of Eurosens...

Page 14: ...PH 500 0 9Ubat 0 7 V Direct PN A 100 0 7 Ubat 0 4 1 4 V Direct PN A 250 0 7 Ubat 0 4 1 4 V Direct PN A 500 0 7 Ubat 0 4 1 4 V Delta PN A 100 0 6 Ubat 0 8 0 7 V Delta PN A 250 0 6 Ubat 0 8 0 7 V Delta...

Page 15: ...ents provided that storage transport and operation conditions are observed and also the instructions for use that set out in this technical requirement are observed as well 2 Product warranty period 3...

Page 16: ...cle condition should be estimated to make a conclusion regarding installation possibility Table 12 Sequence of actions Action Normal state Recommendations in case of mismatch condition 1 To inspect th...

Page 17: ...of capacity of the pomp that is installed at the vehicle or by experimental method by connection of fuel flowmeter with display for example Direct PN A I to the scheme 2 It is not recommended to inst...

Page 18: ...t be protected from external destructive effects 6 It is not allowed to reduce the internal cross section of the fuel lines on the bends 7 Fuel hoses on the vehicle must be fixed every 0 5 m 8 Fuel ho...

Page 19: ...the engine Excess fuel from the fuel pump and injectors of the engine is discharged back into the tank through relief valve 4 4 2 Installation of fuel flow meters Eurosens Direct On pressure side sch...

Page 20: ...the amount of fuel which is consumed by engine Advantages of the scheme on pressure side Eurosens Direct is set after the regular fuel fine filter Reduced flow resistance on the supply pump suction si...

Page 21: ...Thus to the inlet of supply pump two lines are connected 1 supply from the tank passing through the flow sensor 2 The return fuel pump Thus through the flow sensor Direct goes only the amount of fuel...

Page 22: ...ometimes it is needed to install an additional heater 4 4 4 Installation of Eurosens Delta under Differential scheme In differential scheme the measuring circuit of fuel circulating in the fuel system...

Page 23: ...ump inlet fuel tank Fig 8 Eurosens Delta installation with supply chamber on pressure side Fig 9 Eurosens Delta installation with supply chamber on suction side Advantages of differential installation...

Page 24: ...f the vehicle with mandatory fixing with buckles every 50 cm Make electrical connection in accordance to the passport for the product pin circuit Color wires in the cable 1 VBAT green 2 GND black 3 K...

Page 25: ...www mechatronics by Page 25 30 It is recommended to contact Mechatronics technical support or the nearest service center all contact you can find on our web site http www mechatronics by Fig 12 Simple...

Page 26: ...EUROSENS Fuel flow meters Operation manual ver 1 6 www mechatronics by Page 26 30 Fig 13 Simple diagnostics of the Eurosens Direct P PH PN flow meters continuation...

Page 27: ...EUROSENS Fuel flow meters Operation manual ver 1 6 www mechatronics by Page 27 30 Fig 14 Simple diagnostics of the Eurosens Delta PN flow meters...

Page 28: ...0 C and relative humidity up to 100 at 25 C Do not store Eurosens flow sensors in the same room with substances that cause corrosion of the metal and or contain active agents Storage life of eurosens...

Page 29: ...eters does not contain harmful substances and ingredients that are dangerous to human health and environment during and after the end of life and recycling Eurosens fuel flow meters do not contain pre...

Page 30: ...EUROSENS Fuel flow meters Operation manual ver 1 6 www mechatronics by Page 30 30 Fig 17 Dimensions of the EUROSENS Delta PN RS CAN F Forward supply flow R Return return flow...

Reviews: