Mechatronics Eurosens Delta CAN 250 Operation Manual Download Page 1

 

`                                                               phone:    +375(1771)7‐13‐00 

                                                                                                               e‐mail: [email protected]     

 

 

                                                     

 

Eurosens

 

flowmeters

 

operation

 

manual

 

 

 

 

Summary of Contents for Eurosens Delta CAN 250

Page 1: ...phone 375 1771 7 13 00 e mail office mechatronics by Eurosens flowmeters operation manual...

Page 2: ...selection 5 2 5 Dimensions 6 2 6 Specification 6 2 7 Contents of package 10 2 8 Flow meter design and operation 11 3 WARRANTY 15 4 INSTALLATION RECOMMENDATIONS FOR EUROSENS FLOWMETER 16 4 1 Visual ins...

Page 3: ...their operating features The sources of danger during the installation and operation of the flow sensors are electrical current and working fluid which can be pressurized to 2 5 MPa and have temperat...

Page 4: ...nnormalized pulse only for Direct possible 100 No symbol LCD is not installed Direct 1 PN normalized pulse No symbol not possible 250 232 normalized pulse RS232 interface 500 485 normalized pulse RS48...

Page 5: ...with the safe operation of the Eurosens sensors on petrol engines are assigned to the installer of the equipment Fuel flowmeters Eurosens Direct Delta N RS is a unique equipment that allows to set ind...

Page 6: ...commended to install the flowmeter when there is an air in the supply or return line and also in the fuel system with high capacity pomp when the fuel consumption is not large 2 5 Dimensions See para...

Page 7: ...easure not only the fuel consumption but also the derived parameters the engine is running boiler the fuel consumption and the operating time in different modes during the handling etc These parameter...

Page 8: ...50 1 5 Delta PN A 100 I 0 5 10 50 100 200 1 2 Delta PN A 250 I 0 5 20 125 250 100 1 2 Delta PN A 500 I 1 0 40 250 500 50 1 5 Flows to supply consumption in liters hour 45 10 90 20 160 30 A autonomous...

Page 9: ...lta CAN 250 0 5 20 125 250 100 1 2 Delta CAN 500 1 0 40 250 500 50 1 5 Delta CAN 100 I 0 5 10 50 100 200 1 2 Delta CAN 250 I 0 5 20 125 250 100 1 2 Delta CAN 500 I 1 0 40 250 500 50 1 5 Flows to suppl...

Page 10: ...5 Vibration resistance Max acceleration to 100 m s2 in the frequency range from 5 to 250 Hz Resistance to aggressive environments Oil and petrol resistance Electromagnetic compatibility ECE Regulation...

Page 11: ...number of dimensions of the cover and the housing which provides the optimum rotation of the ring chamber During one rotation of the piston volume of liquid equal to the volume of chamber is displace...

Page 12: ...eat volume of return chamber l Return flow rate l h Temperature in return chamber C Battery charge Firmware version These parameters plus some additional are also displayed in configuration software o...

Page 13: ...ave holes for sealing that allows to determine the facts of unauthorized interference in the fuel system after the installation of the flow sensor 2 8 5 Characteristics of the pulse signal of Eurosens...

Page 14: ...PH 500 0 9Ubat 0 7 V Direct PN A 100 0 7 Ubat 0 4 1 4 V Direct PN A 250 0 7 Ubat 0 4 1 4 V Direct PN A 500 0 7 Ubat 0 4 1 4 V Delta PN A 100 0 6 Ubat 0 8 0 7 V Delta PN A 250 0 6 Ubat 0 8 0 7 V Delta...

Page 15: ...ents provided that storage transport and operation conditions are observed and also the instructions for use that set out in this technical requirement are observed as well 2 Product warranty period 3...

Page 16: ...cle condition should be estimated to make a conclusion regarding installation possibility Table 12 Sequence of actions Action Normal state Recommendations in case of mismatch condition 1 To inspect th...

Page 17: ...of capacity of the pomp that is installed at the vehicle or by experimental method by connection of fuel flowmeter with display for example Direct PN A I to the scheme 2 It is not recommended to inst...

Page 18: ...t be protected from external destructive effects 6 It is not allowed to reduce the internal cross section of the fuel lines on the bends 7 Fuel hoses on the vehicle must be fixed every 0 5 m 8 Fuel ho...

Page 19: ...the engine Excess fuel from the fuel pump and injectors of the engine is discharged back into the tank through relief valve 4 4 2 Installation of fuel flow meters Eurosens Direct On pressure side sch...

Page 20: ...the amount of fuel which is consumed by engine Advantages of the scheme on pressure side Eurosens Direct is set after the regular fuel fine filter Reduced flow resistance on the supply pump suction si...

Page 21: ...Thus to the inlet of supply pump two lines are connected 1 supply from the tank passing through the flow sensor 2 The return fuel pump Thus through the flow sensor Direct goes only the amount of fuel...

Page 22: ...ometimes it is needed to install an additional heater 4 4 4 Installation of Eurosens Delta under Differential scheme In differential scheme the measuring circuit of fuel circulating in the fuel system...

Page 23: ...ump inlet fuel tank Fig 8 Eurosens Delta installation with supply chamber on pressure side Fig 9 Eurosens Delta installation with supply chamber on suction side Advantages of differential installation...

Page 24: ...f the vehicle with mandatory fixing with buckles every 50 cm Make electrical connection in accordance to the passport for the product pin circuit Color wires in the cable 1 VBAT green 2 GND black 3 K...

Page 25: ...www mechatronics by Page 25 30 It is recommended to contact Mechatronics technical support or the nearest service center all contact you can find on our web site http www mechatronics by Fig 12 Simple...

Page 26: ...EUROSENS Fuel flow meters Operation manual ver 1 6 www mechatronics by Page 26 30 Fig 13 Simple diagnostics of the Eurosens Direct P PH PN flow meters continuation...

Page 27: ...EUROSENS Fuel flow meters Operation manual ver 1 6 www mechatronics by Page 27 30 Fig 14 Simple diagnostics of the Eurosens Delta PN flow meters...

Page 28: ...0 C and relative humidity up to 100 at 25 C Do not store Eurosens flow sensors in the same room with substances that cause corrosion of the metal and or contain active agents Storage life of eurosens...

Page 29: ...eters does not contain harmful substances and ingredients that are dangerous to human health and environment during and after the end of life and recycling Eurosens fuel flow meters do not contain pre...

Page 30: ...EUROSENS Fuel flow meters Operation manual ver 1 6 www mechatronics by Page 30 30 Fig 17 Dimensions of the EUROSENS Delta PN RS CAN F Forward supply flow R Return return flow...