Inspection 

Remove UPS from its package and inspect it for damage 
before  installation.    If  any  damage  is  found, re-pack  and 
return the unit to the place of purchase. 

 

Placement 

Install the UPS in a protected area that is free of excessive 
dust and has adequate air flow. DO NOT operate the UPS 
where the temperature and humidity is outside the specific 
limits. 

     

 

Connect to Utility & Charging 

Plug  in  the  AC  input  cord  to  the  wall  outlet.  For  the  best 
results,  suggest  to  charge  the  battery  at  least  4  hours 
before  initial  use.    The  unit  automatically  charges  ts 
battery while connecting to the utility.   

 

Connect the Loads 

Plug in the loads to output receptacles on the rear panel of 
the  UPS.  Simply  turn  on  the  power  switch  of  UPS  unit, 
then  devices  connected  to  the  UPS  will  be  protected  by 
the UPS. 

 

 

 

Connect Modem/Phone Line   

Connect  a  single  modem/phone  line  into  surge-protected 
“IN” outlet on the rear panel of the UPS unit. Connect from 
“OUT” outlet to the computer with phone line cable.   

 

Connect Communication Cable

 

To allow for unattended UPS shutdown/start-up and status 
monitoring,  connect  the  communication  cable  one  end  to 
the  USB  port  and  the  other  to the  communication  port  of 
your  PC.  With  the  monitoring  software  installed,  you  can 
schedule UPS shutdown / start-up and monitor UPS status 
through PC. 

 

Turning On/Off the Unit 

Turn on the UPS unit by pressing the power switch.    Turn 
off the UPS unit by pressing again the power switch. You 
may check the front LED indicators for the status.   

 

Cold Start Function 

When the UPS is off and there is no power utility, it’s still 
possible to cold start the UPS unit to power the loads.   

 

 

Monitoring Software Setup   

Please follow steps below to install the software: 
1. Insert the included CD into CD-ROM drive and then 

follow the on-screen instructions. If there no screen 
shows when inserting the CD after 1 minute, please 
execute setup.exe for initiating software installation. 

2. After  computer  restarts,  the  monitoring  software  will 

appear  as  an  orange  plug  icon 

located  in  the 

system tray. 

TROUBLE SHOOTING 

Problem 

Possible Cause 

Solutions 

No LED display 
on the front 
panel. 

Battery voltage is too low 

Charge the UPS unit up 
to 4

 

hours.   

Battery failure. 

Replace with the same 
type of battery. 

UPS always on 
battery mode 

Power cord loose 

Re-plug the power cord. 

Fuse is burned. 

Replace the same type of 
fuse 

AC utility is too high or too low, 
or there is a blackout 

Normal condition 

During power 
failure, backup 
time is shorten. 

Overload of the UPS. 

Remove some noncritical 
load. 

Battery voltage is too low. 

Charge battery 4 hours or 
more. 

Battery defect due to high 
temperature operation 
environment, or improper 
operation to battery. 

Replace with the same 
type of battery. 

 

SPECIFICATIONS 

MODEL 

ME-650-VU  ME-850-VU  ME-1000-VU  ME-2000-VU 

INPUT 

Capacity 

650VA / 

360W 

850VA / 

480W 

1000VA / 

600W 

2000VA / 

1200W 

Voltage 

110/120 VAC or 220/230/240 VAC 

Voltage Range 

81-145 VAC or 162-290 VAC 

OUTPUT 

AC Voltage Regulation 
(Batt. Mode) 

±10% 

Frequency Range (Batt. 
Mode) 

50Hz or 60Hz ± 1 Hz 

Transfer Time 

Typical 2-6 ms, 10 ms max. 

Waveform (Batt. Mode) 

Simulated Sine Wave 

BATTERY 

Battery Type & Number 

12 V/7 Ah x 

12 V/9 Ah x 

12 V/7 Ah x 2  12 V/9 Ah x 2 

Typical Recharge Time 

4-6 hours recover to 90% capacity 

ALARM 

Battery Mode 

Sounding every 10 seconds 

Low Battery 

Sounding every second 

Overload 

Sounding every 0.5 second 

Fault 

Continuously sounding 

PHYSICAL 

Dimension, DXWXH 
(mm) 

287 x 100 x142 

350 x 146 x 

160 

397 x 146 x 

205 

Net Weight (kgs) 

4.25 

4.9 

8.0 

11.5 

ENVIRONMENT 

Humidity 

0-90 % RH @ 0- 40°C (non-condensing) 

Noise Level 

Less than 40dB 

INTERFACE 

USB Port 

Windows2000/2003/XP/Vista/2008/7, Linux, Unix, and 

MAC 

* Product specifications are subject to change without further notice. 

 

 

 
 
 
 
 
 

CAUTION:   

NEVER connect a laser printer or scanner to the UPS 
unit. This may cause the damage of the unit. 