30750
14MBX
M1
67
3-
Set the selector to MECALAC 1 and pull the left key
towards the back (blocked position) to allow the oil to
circulate (small chamber in the dipper ram).
4-
Measure the difference in pressure between (1 fig. 3)
and (2 fig. 3) using the two manometers.
5-
Turn the screw (1 fig. 4) clockwise in order to increase
the
∆
P
.
Note: The flow meter kit shall remain installed
for adjusting the power regulation.
13 flat spanner
4 male hexagonal spanner
2 manometers, 0-600 bars
Fig. 3 SX18 valve block
MECALAC 1
MECALAC 2
Fig. 4 Equipment pump
Operation
Pressure
(bars)
Measurement
(ref. no.)
Adjustment
(ref. no.)
∆
P
of equipment
15 (+ 1 - 1)
1 fig. 3 and 2 fig. 3
1 fig. 4
1
2
1