Page 39
3084ES Speed Level
TM
- Operator’s Manual
August 2020
Secton 12 - Component Locatons
Lower Controls
ART_3245
Emergency Stop
Hour Meter
Circuit
Breaker
5
Charge Indicator
6
4
Keyswitch
Lower
(Green)
Raise
(Green)
1
Battery
Disconnect
8
2
3
7
Emergency
Lowering
9
Overload
Indicator Light
10
CONTROL
DESCRIPTION
1
Selector Switch
PLATFORM
Select to operate from the platform control panel.
BASE
Select to operate from the base control panel.
OFF
Select to stop operation from either control panel.
2
RAISE Button
Press and hold to elevate the platform. Release to stop elevation.
3
LOWER Button
Press and hold to lower the platform. Release to stop lowering.
4
EMERGENCY STOP
Switch
Press to stop all machine functions. Turn clockwise to reset.
5
Hour Meter
Indicates total elapsed time of machine operation.
6
Charge Indicator
Indicates state of battery charge.
7
Circuit Breaker
Trips when there is excessive electrical load. Push to reset.
8
Battery Disconnect
Battery power supply. Turn OFF and padlock to secure machine from
unauthorized use.
9
EMERGENCY
LOWERING Switch
Push and hold the toggle switch Down to fully lower the platform.
10
Overload
Indicator Light
Light ON indicates too much weight on the platform.
An audible alarm will sound and all machine function will stop.
Remove weight from the platform to restore function and continue.