©Measurlogic
Page 17
MQ0051-20F
7334 S. Alton Way, Centennial CO 80112
Tel: 877-777-6567 Tel: 303-805-5252 Fax: 425-799-4780
e-mail: [email protected]
web: www.measurlogic.com
4.2
Battery
The DTS SMX is fitted with a 3V coin cell battery to support essential core functions. The battery life is
typically 5 years or more. See section 4.2.2 for the replacement procedure.
4.2.1
Battery Specifications
Description:
Lithium Battery Non-Rechargeable
(Primary) 3V Coin, 20.0mm
Manufacturer:
Panasonic or equivalent
Manufacturer Part Number:
CR2032
Nominal Voltage (V):
3
Nominal Capacity (mAH):
225
Continuous Standard Load (mA):
0.2
Operating Temperature (C):
-30 ~ 60
4.2.2
Battery Location and Placement
Figure 4.2b
–
Battery Orientation
•
The coin cell battery is located in the upper left on the main board of the DTS SMX as shown in
figure 4.2a.
•
When replacing the battery make sure that the “+” side of the
battery is facing the same direction
as the
“+” marking
on the battery clip as seen in Figure 4.2b.
Figure 4.2a
–
Location of battery