PCI-DAS64/M1/16 User's Guide
Installing the PCI-DAS64/M1/16
40-pin to 37-pin signal mapping
Signal mapping on the C40-37F-x and the BP40-37 cables is not 1:1.
lists the pin numbers of the
signals on the 40-pin end and the pin numbers of the associated signals on the 37-pin end.
Table 2-5. Signal mapping on the C40-37F-x and BP40-37F cables
40-pin cable end
37-pin cable end
Pin Signal
Name
Pin Signal
Name
1
INTERRUPT IN
1
INTERRUPT IN
2 +5V
20
+5V
3
INTERRUPT ENABLE
2
INTERRUPT ENABLE
4 GND
21
GND
5
Port B 7
3
Port B 7
6
Port C 7
22
Port C 7
7
Port B 6
4
Port B 6
8
Port C 6
23
Port C 6
9
Port B 5
5
Port B 5
10
Port C 5
24
Port C 5
11
Port B 4
6
Port B 4
12
Port C 4
25
Port C 4
13
Port B 3
7
Port B 3
14
Port C 3
26
Port C 3
15
Port B 2
8
Port B 2
16
Port C 2
27
Port C 2
17
Port B 1
9
Port B 1
18
Port C 1
28
Port C 1
19
Port B 0
10
Port B 0
20
Port C 0
29
Port C 0
21 GND
11
GND
22
Port A 7
30
Port A 7
23 N/C
12
N/C
24
Port A 6
31
Port A 6
25 GND
13
GND
26
Port A 5
32
Port A 5
27 N/C
14
N/C
28
Port A 4
33
Port A 4
29 GND
15
GND
30
Port A 3
34
Port A 3
31 N/C
16
N/C
32
Port A 2
35
Port A 2
33 GND
17
GND
34
Port A 1
36
Port A 1
35 +5V
18
+5V
36
Port A 0
37
Port A 0
37 GND
19
GND
38 N/C
39 N/C
40 N/C
For digital signal conditioning, you can connect the BP40-37 cable to a C37FF-
x
or C37FFS-
x
cable, and then
connect one of these cables to the 37-pin connector on MCC’s digital signal conditioning boards. Refer to page
2-10 for a list of compatible boards.
20
1
37
19
20
1
37
19
The red stripe
identifies pin # 1
Figure 2-7. C37FF-x cable
2-9
Summary of Contents for PCI-DAS64/M1/16
Page 1: ......