Declaration of Conformity 

Manufacturer: 

Measurement Computing Corporation 

Address: 

10 Commerce Way 

 

Suite 1008 

 

Norton, MA  02766 

 

USA 

Category: 

Electrical equipment for measurement, control and laboratory use. 

Measurement Computing Corporation declares under sole responsibility that the product 

 

PCI-DAS6013 and PCI-DAS6014 

to which this declaration relates is in conformity with the relevant provisions of the following standards or other 
documents: 

EC EMC Directive 2004/108/EC: General Requirements, EN 61326-1:2006 (IEC 61326-1:2005).  

Emissions:  

 

EN 55011 (2007) / CISPR 11(2003): Radiated emissions: Group 1, Class A 

 

 

EN 55011 (2007) / CISPR 11(2003): Conducted emissions: Group 1, Class A

 

Immunity:  EN 61326-1:2006, Table 3.  

 

IEC 61000-4-2 (2001): Electrostatic Discharge immunity.

 

 

IEC 61000-4-3 (2002): Radiated Electromagnetic Field immunity.

 

 

IEC 61000-4-4 (2004): Electric Fast Transient Burst Immunity.

 

 

IEC 61000-4-5 (2001): Surge Immunity.

 

 

IEC 61000-4-6 (2003): Radio Frequency Common Mode Immunity.

 

 

IEC 61000-4-11 (2004): Voltage Interrupts.

 

 
To maintain compliance to the standards of this declaration, the following conditions must be met. 
 

 

The host computer, peripheral equipment, power sources, and expansion hardware must be CE 
compliant. 

 

All I/O cables must be shielded, with the shields connected to ground. 

 

I/O cables must be less than 3 meters (9.75 feet) in length. 

 

The host computer must be properly grounded. 

 

Equipment must be operated in a controlled electromagnetic environment as defined by Standards EN 
61326-1:2006, or IEC 61326-1:2005. 

 

Declaration of Conformity based on tests conducted by Chomerics Test Services, Woburn, MA 01801, USA in 
July, 2004. Test records are outlined in Chomerics Test Report #EMI3931.04. Further testing was conducted by 
Chomerics Test Services, Woburn, MA. 01801, USA in December, 2008. Test records are outlined in 
Chomerics Test report #EMI5216.08. 

We hereby declare that the equipment specified conforms to the above Directives and Standards. 

 

 

Carl Haapaoja, Director of Quality Assurance 

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Summary of Contents for PCI-DAS6013

Page 1: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Page 2: ...1 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 3: ...CI DAS6014 Analog and Digital I O User s Guide Document Revision 6 May 2009 Copyright 2009 Measurement Computing Corporation Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE w...

Page 4: ...the terms and conditions of sale Harsh Environment Program Any Measurement Computing product that is damaged due to misuse or any reason may be eligible for replacement with the same or similar devic...

Page 5: ...ise under any patent or copyrights of Measurement Computing Corporation All rights reserved No part of this publication may be reproduced stored in a retrieval system or transmitted in any form by any...

Page 6: ...ded input mode 11 Connecting the board for I O operations 12 Connectors cables main I O connector 12 Pin out main I O connector 13 Field wiring and signal termination 16 Chapter 3 Functional Details 1...

Page 7: ...nly 33 Analog output pacing and triggering 34 Analog input output calibration 34 Digital input output 35 Interrupts 35 Counters 36 Configurable AUXIN 5 0 AUXOUT 2 0 external trigger clocks 37 Power co...

Page 8: ...ned to registers bit settings etc bold text Bold text is used for the names of objects on the screen such as buttons text boxes and check boxes For example 1 Insert the disk or CD and click the OK but...

Page 9: ...ilable at a 100 pin I O connector Six are configurable as inputs and three are configurable as outputs Interrupts can be generated by up to seven ADC sources on both boards and by up to four DAC sourc...

Page 10: ...u received with your PCI DAS6013 and PCI DAS6014 and information regarding installation of that software Please read this booklet completely before installing any software or hardware Optional compone...

Page 11: ...fore you install your board The driver needed to run your board is installed with the MCC DAQ software Therefore you need to install the MCC DAQ software before you install your board Refer to the Qui...

Page 12: ...ode When all channels are configured for single ended input mode 16 analog input channels are available In this mode the input signal is referenced to the board s signal ground LLGND The input signal...

Page 13: ...s and accessory equipment Connector type Shielded SCSI 100 pin D type Compatible cables C100HD50 x unshielded ribbon cable x 3 or 6 feet see Figure 1 C100MMS x cable shielded round cable x 1 2 or 3 me...

Page 14: ...89 39 PC 5 V DIO3 88 38 D A OUT1 DIO2 87 37 D A GND DIO1 86 36 D A OUT 0 DIO0 85 35 AISENSE n c 84 34 n c n c 83 33 n c n c 82 32 n c n c 81 31 n c n c 80 30 n c n c 79 29 n c n c 78 28 n c n c 77 27...

Page 15: ...UT DIO4 89 39 PC 5 V DIO3 88 38 D A OUT1 DIO2 87 37 D A GND DIO1 86 36 D A OUT 0 DIO0 85 35 AISENSE n c 84 34 n c n c 83 33 n c n c 82 32 n c n c 81 31 n c n c 80 30 n c n c 79 29 n c n c 78 28 n c n...

Page 16: ...0 are on the short side of the D connector Key Key The red stripe identifies pin 1 The red stripe identifies pin 51 Strain relief is Stamped Pins 51 100 Figure 1 C100HD50 x cable 100 50 51 1 100 50 51...

Page 17: ...th the C100MMS x cable SCB 100 100 conductor shielded signal connection screw terminal box provides two independent 50 pin connections BNC connector boxes BNC 16SE 16 channel single ended BNC connecto...

Page 18: ...d on the memory bus The queue buffer 8K configuration memory stores programmed channel numbers gains and offsets The ADC buffer 8K FIFO First In First Out temporarily stores scanned and converted anal...

Page 19: ...g the start of conversion SSH An active signal that negates at the start of the last conversion in a scan A D STOP Indicates end of an acquisition sequence A D CONVERT ADC convert pulse default SCANCL...

Page 20: ...PACER GATE LOCAL BUS PCI BUS 5V 32 BIT 33 MHZ Boot EEPROM EXT CTR1 CLK CTR1 CLK USER COUNTER 2 Control 82C54 USER COUNTER 1 CTR2 GATE CTR1 GATE CTR2 OUT CTR1 OUT DIO 8 BITS DIO 7 0 DAC0 DAC1 PCI DAS6...

Page 21: ...400 ns Figure 4 SCANCLK signal timing A D START TRIGGER signal Use the A D START TRIGGER signal for conventional triggering when you only need to acquire data after a trigger event Figure 5 shows the...

Page 22: ...op Trigger Scan Counter Don t care Figure 8 A D STOP TRIGGER Pre triggered data acquisition example The A D STOP TRIGGER signal signifies when the circular buffer should stop and when the specified nu...

Page 23: ...edge of which indicates the start of a channel scan tw tw 50 ns Figure 11 STARTSCAN start of scan timing SSH signal The SSH signal can be used as a control signal for external sample hold circuits The...

Page 24: ...t The A D CONVERT signal is generated by the on board pacer circuit unless the external clock option is in use This signal may be gated by hardware A D PACER GATE or software A D PACER GATE signal The...

Page 25: ...SE D A START TRIGGER signal The D A START TRIGGER signal is used to hold off output scans until after a trigger event Any AUXIN pin can be programmed to serve as the D A START TRIGGER signal It is als...

Page 26: ...signal polarity is software selectable DAC outputs update within 100ns of the selected edge The D A CONVERT pulses should be no less than 100 s apart When used as an output the D A CONVERT signal may...

Page 27: ...m tp tw tp 50 ns minimum Figure 21 D A EXTERNAL TIMEBASE signal timing General purpose counter signal timing The general purpose counter signals are CTR1 CLK CTR1 GATE CTR1 OUT CTR2 CLK CTR2 GATE CTR2...

Page 28: ...1 OUT signal for counter mode 0 and mode 2 For detailed information on counter operations please refer to the data sheet on our web site at www mccdaq com PDFmanuals 82C54 pdf CTR1 CLK TC CTR1 OUT Mod...

Page 29: ...Figure 26 CTR2 GATE signal timing CTR2 OUT signal This signal is present on the CTR2 OUT pin The CTR2 OUT signal is the output of one of the two user s counters in an industry standard 82C54 chip Figu...

Page 30: ...n values Calibration theory Analog inputs are calibrated for offset and gain Offset calibration for the analog inputs is performed directly on the input amplifier with coarse and fine trim DACs acting...

Page 31: ...djust the gain of the DAC A separate DAC is used to adjust offset on the final output amplifier The calibration circuits are duplicated for both analog outputs see Figure 29 Trim DAC Ref D A Gain Adju...

Page 32: ...f pre trigger samples 16 Meg post trigger samples ADC pacer out Available at user connector A D PACER OUT RAM buffer size 8 K samples Data transfer DMA Programmed I O DMA modes Demand or non demand us...

Page 33: ...fied range 200 kS s 2 Multiple channel single input range Per specified range 200 kS s 3 Single channel multiple input ranges Default to value for cbAInScan range parameter 200 kS s Note 2 For conditi...

Page 34: ...at the user connector Samples are gathered at the maximum specified single channel sampling rate This specification applies to both single ended and differential modes of operation Table 4 Analog inpu...

Page 35: ...DAC gate source software programmable External digital D A START TRIGGER Software gated DAC gating modes External digital Programmable active high or active low level or edge DAC trigger sources Exter...

Page 36: ...tware programmable DAQ_ACTIVE Interrupt is generated when a DAQ sequence is active DAQ_STOP Interrupt is generated when A D Stop Trigger In is detected DAQ_DONE Interrupt is generated when a DAQ seque...

Page 37: ...rce stability 50ppm Counter n gate Available at connector CTRn GATE Counter n output Available at connector CTRn OUT Clock input frequency 10 MHz max High pulse width clock input 15 ns min Low pulse w...

Page 38: ...A pulse indicating start of conversion SSH Active signal that terminates at the start of the last conversion in a scan A D STOP Indicates end of scan A D CONVERT ADC convert pulse SCANCLK Delayed vers...

Page 39: ...chanical Card dimensions PCI half card 174 4 mm L x 100 6 mm W x 11 65 mm H Main connector and pin out Connector type Shielded SCSI 100 D type Compatible cables C100HD50 x unshielded ribbon cable x 3...

Page 40: ...c 23 n c 73 n c 24 n c 74 n c 25 n c 75 n c 26 n c 76 n c 27 n c 77 n c 28 n c 78 n c 29 n c 79 n c 30 n c 80 n c 31 n c 81 n c 32 n c 82 n c 33 n c 83 n c 34 n c 84 n c 35 AISENSE 85 DIO0 36 D A OUT...

Page 41: ...c 74 n c 25 n c 75 n c 26 n c 76 n c 27 n c 77 n c 28 n c 78 n c 29 n c 79 n c 30 n c 80 n c 31 n c 81 n c 32 n c 82 n c 33 n c 83 n c 34 n c 84 n c 35 AISENSE 85 DIO0 36 D A OUT 0 86 DIO1 37 D A GND...

Page 42: ...requency Common Mode Immunity IEC 61000 4 11 2004 Voltage Interrupts To maintain compliance to the standards of this declaration the following conditions must be met The host computer peripheral equip...

Page 43: ...rporation 10 Commerce Way Suite 1008 Norton Massachusetts 02766 508 946 5100 Fax 508 946 9500 E mail info mccdaq com www mccdaq com Artisan Technology Group Quality Instrumentation Guaranteed 888 88 S...

Page 44: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Reviews: