background image

 

Your new Measurement Computing product comes with a fantastic extra — 

Management committed to your satisfaction! 

Refer to 

www.mccdaq.com/execteam.html

 for the names, titles, and contact information of each key executive at Measurement 

Computing. 

 

Thank you for choosing a Measurement Computing product—and congratulations! You own the finest, and you can now enjoy 
the protection of the most comprehensive warranties and unmatched phone tech support. It’s the embodiment of our two 
missions: 

!

 

To offer the highest-quality, computer-based data acquisition, control, and GPIB hardware and software available—at 
the best possible price. 

!

 

To offer our customers superior post-sale support—FREE. Whether providing unrivaled telephone technical and sales 
support on our latest product offerings, or continuing that same first-rate support on older products and operating 
systems, we’re committed to you! 

Lifetime warranty:

 Every hardware product manufactured by Measurement Computing Corporation is warranted against 

defects in materials or workmanship for the life of the product. Products found defective are repaired or replaced promptly.

 

Lifetime Harsh Environment Warranty®: 

We will replace any product manufactured by Measurement Computing 

Corporation that is damaged (even due to misuse) for only 50% of the current list price. I/O boards face some tough operating 
conditions

some more severe than the boards are designed to withstand. When a board becomes damaged, just return the unit 

with an order for its replacement at only 50% of the current list price. We don’t need to profit from your misfortune. By the way, 
we honor this warranty for any manufacturer’s board that we have a replacement for. 

30 Day Money Back Guarantee:

 You may return any Measurement Computing Corporation product within 30 days of 

purchase for a full refund of the price paid for the product being returned. If you are not satisfied, or chose the wrong product by 
mistake, you do not have to keep it. Please call for an RMA number first. No credits or returns accepted without a copy of the 
original invoice. Some software products are subject to a repackaging fee. 

These warranties are in lieu of all other warranties, expressed or implied, including any implied warranty of merchantability or 
fitness for a particular application. The remedies provided herein are the buyer’s sole and exclusive remedies. Neither 
Measurement Computing Corporation, nor its employees shall be liable for any direct or indirect, special, incidental or 
consequential damage arising from the use of its products, even if Measurement Computing Corporation has been notified in 
advance of the possibility of such damages.

 

 

  

ii 

HM PCI-DAS-TC.doc 

Summary of Contents for PCI-DAS-TC

Page 1: ......

Page 2: ...PCI DAS TC Thermocouple Input Board User s Guide Document Revision 4 July 2006 Copyright 2006 Measurement Computing Corporation ...

Page 3: ...on that is damaged even due to misuse for only 50 of the current list price I O boards face some tough operating conditions some more severe than the boards are designed to withstand When a board becomes damaged just return the unit with an order for its replacement at only 50 of the current list price We don t need to profit from your misfortune By the way we honor this warranty for any manufactu...

Page 4: ...granted by implication or otherwise under any patent or copyrights of Measurement Computing Corporation All rights reserved No part of this publication may be reproduced stored in a retrieval system or transmitted in any form by any means electronic mechanical by photocopying recording or otherwise without the prior written permission of Measurement Computing Corporation Notice Measurement Computi...

Page 5: ...ons 2 3 Connectors cables main I O connector 2 3 Pin out main I O connector 2 3 Field wiring signal termination and conditioning 2 4 Chapter 3 Programming and Developing Applications 3 1 Programming languages 3 1 Packaged applications programs 3 1 Register level programming 3 1 Chapter 4 Functional Details 4 1 PCI DAS TC Block diagram 4 1 CIO STA TC screw terminal adapter board 4 2 Open thermocoup...

Page 6: ...e names of manuals and help topic titles and to emphasize a word or phrase For example The InstaCal installation procedure is explained in the Quick Start Guide Never touch the exposed pins or circuit connections on the board Where to find more information The following electronic documents provide information relevant to the operation of your PCI DAS TC MCC s Specifications PCI DAS TC the PDF ver...

Page 7: ...othermal bar to maintain the screw terminals at a constant temperature You can configure open thermocouple detection OTD for each input channel with on board switches The CIO STA TC screw terminal board is mounted in an enclosure to minimize errors caused by local currents or air drafts The PCI DAS TC board is shipped fully calibrated from the factory with calibration coefficients stored in nonvol...

Page 8: ... a brief description of the software you received with your PCI DAS TC and information regarding installation of that software Please read this booklet completely before installing any software or hardware Optional components PCI DAS TC is also available as a kit MCC part number PCI DAS TC If you ordered this kit the optional components listed here are included with your shipment screw terminal bo...

Page 9: ...aq com Installing the software Refer to the Quick Start Guide for instructions on installing the software on the Measurement Computing Data Acquisition Software CD This booklet is available in PDF at www mccdaq com PDFmanuals DAQ Software Quick Start pdf Installing the PCI DAS TC The PCI DAS TC board is completely plug and play There are no switches or jumpers to set on the board Configuration is ...

Page 10: ...ntrolled You can select some of the configuration options using InstaCal such as the thermocouple type CJC on off voltage or thermocouple gain and temperature units Once selected any program that uses the Universal Library will initialize the hardware according to these selections Connecting the board for I O operations Connectors cables main I O connector Table 2 1 Table 2 1 Board connector appli...

Page 11: ... You can use the following screw terminal adapter board with CJC sensor and isothermal block to terminate field signals and route them into the PCI DAS TC using the C37FFS x cable CIO STA TC Isothermal block with CJC sensor Details on this product are available on our web site at www mccdaq com cbicatalog cbiproduct asp dept_id 116 pf_id 1209 2 4 ...

Page 12: ...have drivers for your board If the package you own does not have drivers for your board please fax or e mail the package name and the revision number from the install disks We will research the package for you and advise how to obtain drivers Some application drivers are included with the Universal Library package but not with the application package If you have purchased an application package di...

Page 13: ...el Calibration Fout CLK IN V F Converter 10V Ref Gain Mux Input AMP 20 Channel Mux 37 Pin 10V Prec Ref 5V ISO 15V ISO 15V ISO Input Connector 9 9V CJC AGND TC Input Channels 0 15 Screw Terminal CJC Open Thermocouple Detection Switches 0 15 External DAS TC Screw Terminal For CJC 15ISO Thermocouple Input Channels Isolated Analog Input Section 32 BIT 33 MHz 5V PCI BUS PLX9050 PCI Interface Control Si...

Page 14: ...re a series of 20 MΩ resistors that can be connected between the terminal of the thermocouple and a known voltage that is larger than any allowable thermocouple output The 20 MΩ resistors are large enough so that they do not affect the readings from the thermocouples If a thermocouple junction should open a 20 MΩ will drive the input voltage high enough so the software can recognize that it is not...

Page 15: ...the microcontroller gets the raw frequency count from TIMER0 translates that into bits factors in the CJC correction and gain offset calibration then refers to a previously stored lookup table stored in ROM There is a separate table for each thermocouple The lookup tables are a method to optimize the linearization by using more reference points along areas of greatest temperature voltage change in...

Page 16: ...21 6 msec 60 Hz typical 22 1 msec maximum 7 4 msec 400 Hz typical 7 9 msec maximum This is the total time to convert the channel process the data and provide a delay to switch the gain and channel Linearity error A D specs 0 05 4 MHz clock Gain drift A D specs 75 ppm C max Zero drift A D specs 50 uV C max Power supply rejection ratio 0 01 V Overvoltage protection 40 V to 55 V CMRR 60 Hz 80 dB mini...

Page 17: ...ith each calibration Processor reset On power up watchdog timeout or software command Processor boots within one second of reset Active low Watchdog timer 1 6 seconds nominal Processor generates watchdog disable signal after boot up Temperature units Programmable for conversion to C or F Interrupts INTA mapped to IRQn by PCIBIOS at boot time Interrupt enable Programmable Interrupt sources Dual por...

Page 18: ...ironmental specifications Operating temperature range 0 to 50 C Storage temperature range 20 to 70 C Humidity 0 to 90 non condensing Main connector and pin out Table 11 Main connector specifications Connector type 37 pin D type Compatible cable C37FFS x Compatible accessory product with C37FFS x cable CIO STA TC screw terminal adapter board None CH14 HI CH7 LO CH13 LO CH13 HI CH11 LO CH11 HI CH9 L...

Page 19: ...ssions Immunity EN55024 EN61000 4 2 1995 Electrostatic Discharge immunity Criteria A EN61000 4 3 1997 Radiated Electromagnetic Field immunity Criteria A EN61000 4 4 1995 Electric Fast Transient Burst immunity Criteria A EN61000 4 5 1995 Surge immunity Criteria A EN61000 4 6 1996 Radio Frequency Common Mode immunity Criteria A EN61000 4 8 1994 Power Frequency Magnetic Field immunity Criteria A EN61...

Page 20: ...Measurement Computing Corporation 10 Commerce Way Suite 1008 Norton Massachusetts 02766 508 946 5100 Fax 508 946 9500 E mail info mccdaq com www mccdaq com HM PCI DAS TC doc ...

Reviews: