Page 1: ...tion 230VAC 2A 1 5A Input voltage range 10 7V 15V 21 4V 30V Low voltage alarm 10 7 V 21 4 V Low voltage shutdown 10 V 20 V Efficiency up to 85 Dimensions mm 415 x 283 x 100 Weight 5 75 kg Fault Cause Remedy No output voltege LED not Illuminated Bad connection between bat tery and inverter Internal fuses defect Check the cables and contact In this case send the unit back to supplier No output volta...
Page 2: ...egative cable to the white negative terminal Connect the positive cable to the red positive terminal 5 I 1 Warningl In order for the integrated residual current operated protective device of the 150S 12NE and 150S 24NE inverters to work properly the earth connection of the inverter must be electrically connected to the chassis of the vehicle or boat Lay the flexible earth cable from the earthing p...