background image

File Name:RSP-2400-SPEC   2016-07-26

Safety: UL/EN/IEC 60950-1

EMC: EN 55022 / 55024

Factory control or automation apparatus

Test and measurement instrument

Laser related machine

Burn-in facility

Digital broadcasting

RF application

Features

Certificates

Applications 

2400W Power Supply with Single Output

R S P - 2 4 0 0

s e r i e s

Model Encoding / Order Information

Description 

RSP-2400 is a 2.4KW single output enclosed type AC/DC power supply. This series operates for 180~264VAC 
input voltage and offers the models with the DC output mostly demanded from the industry. Each model is   
cooled by the built-in fan with fan speed control, working for the temperature up to 70 . Moreover, RSP-2400 

,

provides vast design flexibility by equipping various built-in functions such as the output programming, 
active current sharing, remote ON-OFF control, auxiliary power, etc. 

24

RSP-

-

2400

Series name

Output wattage

Output voltage  (12V/24V/48V)

AC input 180~264VAC

Built-in active PFC function

High efficiency up to 91.5%

Forced air cooling by built-in DC fan 

Output voltage programmable

Active current sharing up to 7200W (2+1)

Built-in remote ON-OFF control / remote sense / 

    auxiliary power   power OK signal

/

Protections: Short circuit / Overload / Over voltage 

                        / Over temperature

Optional conformal coating

5 years warranty

Bauar

Sicherheit

egel

ge

ma

t gepruft

od

be

www.
ID 2000000000

tuv.com

wac

g

o s

7

Dimension

L

278

10.9

W

177.8

H

63.5(2U)

(2U)

mm
inch

2.5

*
*
*

*
*
*

Summary of Contents for RSP-2400-12

Page 1: ...peed control working for the temperature up to 70 Moreover RSP 2400 provides vast design flexibility by equipping various built in functions such as the output programming active current sharing remote ON OFF control auxiliary power etc 24 RSP 2400 Series name Output wattage Output voltage 12V 24V 48V AC input 180 264VAC Built in active PFC function High efficiency up to 91 5 Forced air cooling by...

Page 2: ...The power supply is considered a component which will be installed into a final equipment All the EMC tests are been executed by mounting the unit on a mm mm metal plate with 1mm of thickness The final equipment must be re confirmed that it still meets EMC directives 720 360 For guidance on how to perform these EMC tests please refer to EMI testing of component power supplies as available on http ...

Page 3: ... T P O L P 76 78 80 82 84 86 88 90 92 10 20 30 40 50 60 70 80 90 100 2400W Power Supply with Single Output RSP 2400 series Derating Curve AMBIENT TEMPERATURE LOAD 20 40 60 50 80 100 20 0 10 20 30 40 50 60 70 HORIZONTAL Static Characteristics INPUT VOLTAGE V 60Hz 100 90 80 70 60 50 LOAD 180 185 190 195 200 210 220 230 240 250 264 MODEL INPUT 12V 2000 4W 2400W 2400W 166 7A 100A 50A 180 264VAC 24V 48...

Page 4: ...onents may be damaged and the power supply unit may thus be out of order The Remote Sense compensates voltage drop on the load wiring up to 0 25V 1 Remote Sense The rated current should change with the Output Voltage Programming accordingly MODEL PV Range 12V 2 4 13 2V 24V 4 8 28V 48V 9 6 56V Caution The power supply by factory default also the assumption for other sections is shipped with S V on ...

Page 5: ...tor likewise and OLP PIN9 OL SD PIN10 on CN3 are shorted when shipped Example 3 2 A Example 3 2 B Example 3 2 C SW Logic Power supply output ON SW Open SW Open SW Open Power supply output OFF SW Close SW Close SW Close 3 Remote ON OFF Remote ON OFF is activated by the configuration with respect to CN1 CN2 and CN3 as shown in the following diagram AUX 12V typ 12V typ 12V typ Internal Internal Inter...

Page 6: ...ut of alarm P OK Relay Contact Output of alarm P OK2 TTL Signal The signal turns to be High when the power supply is under 80 of the rated output voltage or say Power Fail High or open External applied voltage 500mA max High or open External applied voltage 10mA max R V Fig 4 2 Internal circuit of P OK2 Open collector method External voltage and R The max sink is 10mA and 30V P OK GND2 P OK2 R V 0...

Page 7: ...ent must not exceed the value determined by the following equation Maximum output current at parallel operation Rated current per unit Number of unit 0 9 File Name RSP 2400 SPEC 2016 07 26 2400W Power Supply with Single Output RSP 2400 series 1 Insert the shorting connector on CN3 that is shown in Fig 5 2 the Overload Protection Type will be constant current limiting with delay shutdown after 5 se...

Page 8: ...it 1 unit 2 unit 2 unit 2 unit 3 unit 3 unit 3 N1 N1 N1 L1 L1 L1 FG FG FG L2 L2 L2 N2 N2 N2 FG2 FG2 FG2 L3 L3 L3 N3 N3 N3 FG3 FG3 FG3 220V 380V 110V 190V Users can exploit three units of RSP 2400 unit 1 unit 2 unit 3 to work with 3 power system Please refer to following diagrams for configuration ψ File Name RSP 2400 SPEC 2016 07 26 2400W Power Supply with Single Output RSP 2400 series ...

Page 9: ...ounting Instruction Hole No Recommended Screw Size MAX Penetration Depth L Recommended mounting torque 1 5mm M4 Control Pin No Assignment HRS DF11 8DP 2DS or equivalent CN1 CN2 CN1 and CN2 are connected internally Mating Housing Terminal HRS DF11 8DS or equivalent HRS DF11 SC or equivalent 7 1 Kgf cm 0 Mounting Screw Mounting Surface Chassis of RSP 2400 L 1 1 1 1 1 1 Pin No 1 2 Function RCG RC Des...

Page 10: ...n Manual Please refer to http www meanwell com webnet search InstallationSearch html AC Input Terminal Pin No Assignment Pin No 1 3 2 Assignment Diagram M x a imum mounting torque 18Kgf cm AC L AC N FG 2 1 10 9 Control Pin No Assignment HRS DF11 10DP 2DS or equivalent CN3 Mating Housing Terminal HRS DF11 10DS or equivalent HRS DF11 SC or equivalent Pin No 1 2 Function P OK GND P OK Description Pow...

Page 11: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Mean Well RSP 2400 12 RSP 2400 24 RSP 2400 48 ...

Reviews: