3
Advantage of pulse stage: Use pulse current to revive aged battery.
Advantage of recond stage: Allow full charge of battery.
Advantage of Float and Maintain stage: After LED turns green, maintenance charge is provided so the battery is always in a full
state. User will have access to a full battery whenever it is disconnected from the charger.
5.2 "8" stage charging (Selection switch to "8" stage)
The charger can be turned ON/OFF by using the "Remote Control" function.
6. Function description
6.1 Remote Control
The charger features user selectable 2 or 8 stage charging. The charging profile is selected by moving the slide switch on the back
panel.
6.2 2 or 8 stage Charging mode Select
SW
9
10
CN100
RY13
NC
RY15
GND
RC-
RY13
NC
RY15
RTH
RC+
1
2
Between RC+(pin10)
and RC-(pin9)
SW Open
SW Short
Charger
ON
OFF
+
Battery
-
8 Stage
Power
2 Stage
10
1 2
3 4
5 6
7 8
9
Switch
Turn right
Turn left
Charging mode
2 stage charging
8 stage charging
8 Stage
2 Stage
+
Battery
-
8 Stage
Power
2 Stage
10
1 2
3 4
5 6
7 8
9
Charge
Current
stage 1
stage 2
stage 3
stage 4
stage 5
stage 6
stage 7
stage 8
Charge
Voltage
Pulse
Soft
Start
Constant
Current
Constant
Voltage
Analysis
Recond
Float
Maintain
Orange
Green
Color of
LED
Figure 5.2 8 Stage Charging Curve
Start
Pulse
Float
Analysis
Recond
Soft
Start
Battery
Maintain
Battery
Battery
Battery
Battery
Current
Voltage
Battery
Battery
Constant
Constant
Battery
Summary of Contents for PB-600
Page 1: ...PB 600 Instruction Manual ...